AERF SRM L Instruction Manual Download Page 2

4.1 

TRANSMITTER RADIO PROGRAMMING

4.2 

MEMORY RESET

4. TRANSMITTER MANUAL PROGRAMMATION

GB

PROG.

1.5s

PROG.

1 X BIP

1 X BIP

RELEASE

PRESS BUTTON

PROG. EMIS

10s

SAVE & EXIT

2 X BIPS

WAIT

PRESS BUTTON

ON

LED ON

OFF

LED OFF

1 X BIP

1 X BIP

MUST HAVE A

TRANSMITTER RECORDED

IN A RECEIVER

1.5s

10s

PUSH

BUTTON

RELEASE

WAIT

PUSH A

SPECIAL

FUNCTION

A

A

B

A

SAVE & EXIT

2 X BIPS

ON

LED ON

OFF

LED OFF

1 X BIP

SAVE & EXIT

2 X BIPS

PROG.

1.5s

PULSAR

PROG.

10s

PROG.

5s

WAIT

RELEASE

# BIPS

KEEP IT 

PRESSED

ON

LED ON

OFF

LED OFF

WARNING!!

- Equipment installation and start-up, can only be executed 
by qualified personal. 

CE DECLARATION OF CONFORMITY 

Aplicaciones electrónicas y de Radiofrecuencia S.L  Pol. Sot dels Pradals C/ Sot dels pradals, 4  08500 
Vic (Barcelona) B61840732 DECLARES, under her own responsibility that product It is designed and 
manufactured in accordance with the directives LV 2006/95/CE of Low Voltage, EMC 2004/108/CE of 
Electromagnetic  Compatibility  ,  2006/42/CE  Machines  directive  and  is  designed  to  control  doors  in 
accordance  with  standard  EN13241-1  (2004)  and  complies  with  the  requirements  of  the  R&TTE 
99/05/CE  European  parliament  directive  of  March  9th  1999.  This  directive  was  transposed  to  the 
Spanish legislation by means of Real Decree 1890/2000 in November 20th of 2000, directive 1999/5/CE 
spectrum  radio  electric  protection,  electromagnetic  compatibility  directive  2004/108/CE. 

For  more 

information visit the website www.aerf.eu

 Power

230V AC +/- 10%  

 Max. Power consumption

0.5A (230v) 65mA(12V) 80mA(24V)

Outputs:

Fixed outputs

2 Relay 1A/30V

 Available codes

2.097.152.281 Millions

Encryption technology

Hopping code

Key Encryption

64 bits

Detection of errors during transmission

2 CRC bits

Error detection

31/255/1000 different codes

Number of codes

Self learning

 Fuction selection:

1 relay

Memorizes in function of the code

2 relays or more

Predeterminated function or program

Latch relays

Position 1 programable

Frecuency

433.92MHz OR 868,35MHz

Certificates

ETS300-220/ETS300-683

Spurious emissions

< -57dBm

Sensitivity

< -104dBm

Range

60m

Access control

YES

Temperature

0 to 70º

Antenna

17cm / 8,5cm

TECHNICAL SPECIFICATIONS

2 - 2

SRM H

2

0

/0

5

/1

4

65mA(12V) 80mA(24V)

12/24 V AC +/- 10%

SRM L

Reviews: