TF6581_C_NOT_INST_C02_SENSOR_MODBUS 

Aereco S.A.

7. 

TECHNICAL DATA

S-C02/T Modbus sensor

Standard code

CAP1668

Data points

CO

2

 and temperature

CO

2

 specifications

Measurement principle

NDIR (non-dispersive infrared technology)

Sensor Type

Dual wavelength

Working range

0…2000 ppm C0

2

Accuracy at 25 °C and 1013 mbar 

< ± (50 ppm +2 % of measuring value)

Response Time

105s with measured data averaging 60s without measured data averaging

Temperature dependency

typ. 2ppm CO2/°C (0...50°C / 32...122°F)

Measuring time interval

1h (default), use Synch operation (Modbus register table) for immediate measurement

Calibration interval 

>5 years

Built-in temperature sensor

Temperature working range

2°C to 50°C

Accuracy 

0.5°C ensured at 25°C

Conversion Gain 

10mV/°C

Electrical specifications 

Power supply 

12 VDC

Power consumption (standby mode)

10mA

Power consumption (measuring mode)

135mA Max

Connection type

2xRJ45 shielded

Communication 

Protocol type

Modbus RTU, RS485 physical layer 

Baud rate

9600bps

Data length

16bits

Housing

Material

ABS

Color

white

Protection 

IP 20

Weight

80.5g

Installation type

Ceiling and Wall-mounted,indoor

8. 

WARRANTY

This guarantee is valid for two years from the original date of purchase of your appliance, for faults 
of the appliance, which have been caused by faulty construction. On these conditions, Aereco 
guarantee the replacement or the supply of the equipment found to be defective after inspection by 
its after sales service. In any case, the warranty may not cover additional costs, of labour, transport 
or compensation of any kind. The warranty does not cover damage due to improper installation 
in this manual, improper use or attempted repair by unauthorized personnel. In case of problems, 
please contact your installer or your reseller.

9. 

CONFORMITY AND STANDARD

The S-C02/T sensor is CE certified.

The S-C02/T sensor complies with the following regulatory references:

Directives 

Standards

EMC

EN 61000-6-3 : 2007 / A1 : 2011 

EN 61000-6-1 : 2007 

Summary of Contents for S-CO2/T

Page 1: ...INSTALLATION AND MAINTENANCE INSTRUCTION ENGLISH VERSION S C02 T MODBUS SENSOR HUB 8 SE ACCESSORIES THIRD PARTY MODBUS SYSTEM TF6581_C_NOT_INST_C02_SENSOR_MODBUS Aereco S A ...

Page 2: ...e it can not be accidentally restored Power cable modification or replacement must only be carried out by qualified personnel or by After sales Service in order to avoid any accident Children being supervised not to play with appliance 1 INTRODUCTION This document presents the installation and maintenance schemes for C02 sensor with Hub 8 SE exhaust compensation valve and third party Modbus system...

Page 3: ...has to be different from a sensor to another one The index numbers must be incremented to each other so that there is no digit jump Example CO2 sensor in living room 4 because Hub SE outlet n 4 is connected to living room Occupancy sensor bedroom A 1 because Hub SE outlet n 1 is connected to bedroom A Occupancy sensor bedroom B 2 because Hub SE outlet n 2 is connected to bedroom B Occupancy sensor...

Page 4: ...E cannot be started accidentally The Hub SE communicates to the other components through Modbus connection All the components are linked other via a daisy chain At the beginning and at the end of the daisy chain a termination is needed B B B C D D A 230 VAC ModBus connection to the CO2 sensor A Hub SE B Sensors C Compensation valve at exhaust D ModBus Termination RJ 45 Supply 230 V 1 5 mm ...

Page 5: ...be manipulated with extreme care 6 2 THE S C02 T ELECTRICAL CONNECTIONS WITH THIRD PARTY MODBUS SYSTEMS Disconnect the electrical power supply before any operations The S C02 T Modbus sensor com municates with other components through Modbus connection which is made by a RS485 interface connected through a double RJ45 connector for daisy chain linking All the components are linked to each other vi...

Page 6: ...etween the controller and the sensor Cut and free the wires coming from the RJ45 connector and connect directly to the terminal block of the controller Second possibility is to use an adaptor RJ45 RJ45 to terminal block 6 4 APPLICATION DEVELOPMENT FOR MODBUS SENSOR Note Aereco developed a customised kit for connecting PC and sensors you can easily order with the reference code below ref ADX1785EX ...

Page 7: ...n type 2xRJ45 shielded Communication Protocol type Modbus RTU RS485 physical layer Baud rate 9600bps Data length 16bits Housing Material ABS Color white Protection IP 20 Weight 80 5g Installation type Ceiling and Wall mounted indoor 8 WARRANTY This guarantee is valid for two years from the original date of purchase of your appliance for faults of the appliance which have been caused by faulty cons...

Page 8: ...SOR_MODBUS Copyright Aereco All data and pictures in this document are non contractual and are subject to change without prior notice Aereco S A 62 rue de Lamirault Collégien 77615 MARNE LA VALLEE CEDEX 3 FRANCE www aereco com ...

Reviews: