background image

 

WS3083 

- 5 - 

Note: When replacing batteries in the transmitter wait two minutes before re-inserting for a proper reset. 

 

Wind Direction 

On  the  edge  of  the  wind  direction  sensor,  there  are  four  letters  -  “N”,  ”E”,  ”S”  and  “W”  representing  the 
directions North, East, South and West. The wind direction sensor has to be adjusted so that the directions on 
the  sensor  are  matching  your  real  location.  A  permanent  wind  direction  error  will  be  introduced  when  the 
wind direction sensor is not positioned correctly during installation. 

 

Batteries 

When  you  need  to  replace  the  batteries  good  quality  non-rechargeable  Alkaline  or  Lithium  batteries  are 
recommended and will receive an appropriate trickle charge from the solar panel. 
   

 

Note:

  Many  rechargeable  batteries  are  1.2V  and  as  such  are  not  suitable  for  this  unit  which  requires  1.5V 

batteries.    Rechargeable  batteries  also  often  leak  their  peak  charge  quickly  which  can  cause  reduced 
transmission range.    As such we recommend avoiding the use of rechargeable batteries.     

 
Note:

 The performance of Alkaline batteries can be significantly reduced in colder environments resulting in 

loss of signal. In this case we recommend the use of Lithium non-rechargeable batteries in the transmitter.   

 
Note:

 Incorrectly inserting the batteries may cause a fault and invalidate the warranty so take care to insert 

them with the correct polarity

 

 

     

Low Battery Indicator 

The transmitter low battery indicator 

  may illuminate when temperatures are outside the range of 

10-35C.    This does not necessarily indicate low batteries and will switch off once the temperature returns to 
this range (also see note above on the use of Alkaline batteries).

 

 

Setup – Sensors

 

                     

 

             

 

Anemometer                                            Wind direction sensor 

 

Summary of Contents for WS3083

Page 1: ...WS3083 1 WS3083 PROFESSIONAL WIRELESS WEATHER STATION WITH USB UPLOAD UV INDEX LIGHT METER ...

Page 2: ...be a result of incorrect setup please contact our local distributor Greenfrog Scientific www greenfrogscientific co uk and their team will be happy to help Genuine faults can typically be diagnosed without requiring the unit to be returned and replacement parts sent quickly if needed Purchased in AUSTRALIA As many issues can be a result of incorrect setup please contact our local distributor Monax...

Page 3: ...PC software package 7 8 9 10 1 11 12 2 13 3 14 4 5 15 6 16 18 17 1 Weather Forecast 2 Barometric Pressure 3 Barometric Trend 4 Date 5 Memory 6 Time 7 Indoor Humidity 8 Indoor Temperature 9 Transmitter Low Battery Icon 10 Outdoor Reception Icon 11 Outdoor Humidity 12 Outdoor Temperature 13 Wind Direction 14 Wind Speed 15 UV Index 16 Rainfall 17 Light 18 Radio Controlled Clock Not available Aus NZ N...

Page 4: ...e RCC signal it will transmit the signal to the Base Station which will display the Radio Controlled Clock icon and the time will synchronise to the RCC time If the Base Station does not receive the RCC signal or loses the signal the RCC icon will not be displayed Positioning Once you have verified that all of the components of the weather station are working they can be positioned in their perman...

Page 5: ...V and as such are not suitable for this unit which requires 1 5V batteries Rechargeable batteries also often leak their peak charge quickly which can cause reduced transmission range As such we recommend avoiding the use of rechargeable batteries Note The performance of Alkaline batteries can be significantly reduced in colder environments resulting in loss of signal In this case we recommend the ...

Page 6: ...WS3083 6 Mounting the dual wind sensor holder Mounting the rain sensor Thermo hygro sensor with solar panel ...

Page 7: ...he solar panel s cable is connected to the input marked Rain on the thermo hygro sensor The solar transmitter The solar transmitter makes use of solar energy to power the instruments it is connected to Note Use 1 5V LR6 AA size batteries For the solar transmitter to function properly make sure the solar receptors on the transmitter are exposed to sunlight and the connectors on the connection cable...

Page 8: ...l 5 press the UP or DOWN key to set the value Level 1 will produce the faintest appearance level 8 the darkest Press the ENTER key to select the following Time zone 12 24h time display default 12h Manual time setting hours minutes Press the UP or DOWN key to set each value Note The radio controlled clock RCC works off the German DCF77 time signal received across large parts of Europe and the UK so...

Page 9: ...ash until the weather condition no longer meets the user s set level When the alarm is sounding press any key to mute the alarm Note Because of the preset default settings it may not be necessary for the majority of users to perform any further basic settings except for Relative Air Pressure see below Changes however can be easily made as below Pressure Press the MENU key three times to select the...

Page 10: ...bled an alarm symbol appears in the display Pressure low alarm press ON OFF to enable disable If the alarm is enabled an alarm symbol appears in the display Maximum pressure value since last reset Resetting the maximum pressure value when both the pressure value and MAX icon are flashing hold the ENTER key for 3s the maximum pressure value will be reset to the current reading Minimum pressure valu...

Page 11: ...ks 7 from 10 forecasts for the upcoming 12 24 hours will be correct Observing the forecast for only a few days is not sufficient to draw any conclusions with respect to accuracy Notes on the pressure sensitivity setting for weather forecasting The pressure threshold can be set to suit the user s requirements for weather forecasting anywhere from 2 4hPa default 2hPa Areas that experience frequent c...

Page 12: ...WS3083 12 Weather forecast symbols Sunny Partly Cloudy Cloudy Rainy Snow Storm Snowstorm Clear Night Cloudy Night ...

Page 13: ...he ENTER key for 3s the minimum indoor humidity value will be reset to the current reading Indoor Temperature Press the MENU key seven times to select the INDOOR TEMPERATURE section the INDOOR TEMPERATURE section digits will start flashing Press the UP or DOWN key to change the temperature unit between C and F Press the ENTER key to select the following modes Indoor temperature high alarm press ON...

Page 14: ...emperature low alarm press ON OFF to enable disable If the alarm is enabled an alarm symbol appears in the display Maximum temperature since last reset Resetting the maximum outdoor temperature value when both the outdoor temperature value and MAX icon are flashing hold the ENTER key for 3s the maximum outdoor temperature value will be reset to the current reading Minimum temperature since last re...

Page 15: ...lect the following modes then press the UP or DOWN key to set the value Wind speed units select between km h mph m s knots bft Wind speed high alarm press ON OFF to enable disable If the alarm is enabled an alarm symbol appears in the display Wind direction alarm press ON OFF to enable disable If the alarm is enabled an alarm symbol appears in the display Maximum wind speed since last reset Resett...

Page 16: ...ER key for 3s the maximum rain value will be reset to the current reading Clearing Total rainfall when both the Total rain value and the word CLEAR are flashing hold the ENTER key for 3s the Total value will be reset to zero 1h 24h Week and Month rain values will be reset to zero automatically Memory Press the HISTORY key to activate the history data display Press the DOWN key to toggle backwards ...

Page 17: ...processed and displayed by means of a PC Software Download Note No CD is contained with this unit please download the latest software and Basic Installation Guide by entering the link below into your browser s address bar http www boxcn net CumulusDownload This software allows the display storage and printing of historical data In addition the software allows the data to be uploaded and displayed ...

Page 18: ... wind speed appears to be under reporting When set to Average wind speed is measured as the average speed recorded over the 48 second period between transmissions In gusty weather this can appear as though it is under reading Set this to Gust see Wind section above to view the maximum wind speed during each 48 second period My rain gauge is under reporting rainfall or not recording it at all Remov...

Page 19: ...teries Remote sensor 2xAA 1 5V batteries Contact Information Purchased in UK EU Please contact our local distributor Greenfrog Scientific www greenfrogscientific co uk and their team will be happy to help Genuine faults can typically be diagnosed without requiring the unit to be returned and replacement parts sent quickly if needed Purchased in AUSTRALIA Please contact our local distributor Monax ...

Page 20: ...ve 1999 5 EC A copy of the signed and dated Declaration of Conformity is available on request from contact aercusinstruments com COUNTRIES RTTE APPROVAL COMPLIED All EU countries This handbook may contain mistakes and printing errors The information in this handbook is regularly checked and corrections made in the next issue We accept no liability for technical mistakes or printing errors or their...