background image

12

DIMENSIONI - DIMENSIONS (in mm)

ØA

B

C

D

E

F

h

Peso/Weigth

(Kg)

QBX100

100

606

452

416

370

384

247

9

QBX125

125

606

452

416

370

384

247

9

QBX150

150

606

452

416

370

384

247

9,5

QBX200

200

542

455

416

370

384

255

10

COMANDI ESTERNI (su richiesta) - REMOTE CONTROLLER (on request)

Fig.7

CTRL-M

Fig.8

SEL-3V

era

a

q

il

a

u

This document is protected by privacy and copyright laws. No part of this document may be reproduced, adapted, trasmitted or

Peso/Weight:

-

Scala/Scale:

Codice/Code:

No. Dis/No. Drawing:

1:1

A

RCHI

V

IO

 CA

D:

-

-

-

-

-

Firma/Sign.

Data/Date

Descrizione/Description

Rev.

-

Firma/Signature:

Data/Date:

Materiale/Material:

Descrizione/Description:

AERAULIQA SRL

Sede legale / Registered office: via Corsica 10, 25125 Brescia

Sede operativa / Warehouse-offices: 

via M.Calderara 39/41, 25018 Montichiari(BS)

Tel: +39 030 674681 Fax: +39 030 6872149

C.F. e P.IVA 03369930981 - REA BS-528635

www.aerauliqa.it

Questo documento è protetto dalle leggi vigenti in materia di privacy e copyright. Nè è vietata la copia, la diffusione senza

autorizzazione di Aerauliqa srl

disclosed without the specific written consent of Aerauliqa srl. All right are reserved.

T:

\A

rc

hiv

io

 P

ro

ge

tti 

In

du

st

ria

le

\In

-L

in

e_

B

ox

\d

ef

in

iti

vo\

Q

B

ox

-d150x

150\

VED DIS

AQD.00328.00

CASSONETTO DI ESTRAZIONE CENTRIFUGO

31/05/2016

NELSON JAMES K.

PBX00001

A

PBX00000

100

125
150

Codice

Descrizione

A

PBX00002

QBX100

A

QBX125
QBX150

 122 

 125 

 247 

 = 

 = 

 = 

 606 

 = 

 452 

 = 

 = 

 = 

 416 

 384 

 = 

 370 

606

452

era

a

q

il

a

u

This document is protected by privacy and copyright laws. No part of this document may be reproduced, adapted, trasmitted or

Peso/Weight:

-

Scala/Scale:

Codice/Code:

No. Dis/No. Drawing:

1:1

A

RCHI

V

IO

 CA

D:

-

-

-

-

-

Firma/Sign.

Data/Date

Descrizione/Description

Rev.

-

Firma/Signature:

Data/Date:

Materiale/Material:

Descrizione/Description:

AERAULIQA SRL

Sede legale / Registered office: via Corsica 10, 25125 Brescia

Sede operativa / Warehouse-offices: 

via M.Calderara 39/41, 25018 Montichiari(BS)

Tel: +39 030 674681 Fax: +39 030 6872149

C.F. e P.IVA 03369930981 - REA BS-528635

www.aerauliqa.it

Questo documento è protetto dalle leggi vigenti in materia di privacy e copyright. Nè è vietata la copia, la diffusione senza

autorizzazione di Aerauliqa srl

disclosed without the specific written consent of Aerauliqa srl. All right are reserved.

T:

\A

rc

hiv

io

 P

ro

ge

tti 

In

du

st

ria

le

\In

-L

in

e_

B

ox

\d

ef

in

iti

vo\

Q

B

ox

-d150x

150\

VED DIS

AQD.00328.00

CASSONETTO DI ESTRAZIONE CENTRIFUGO

31/05/2016

NELSON JAMES K.

PBX00001

A

PBX00000

100

125
150

Codice

Descrizione

A

PBX00002

QBX100

A

QBX125
QBX150

 122 

 125 

 247 

 = 

 = 

 = 

 606 

 = 

 452 

 = 

 = 

 = 

 416 

 384 

 = 

 370 

247

era

a

q

il

a

u

This document is protected by privacy and copyright laws. No part of this document may be reproduced, adapted, trasmitted or

Peso/Weight:

-

Scala/Scale:

Codice/Code:

No. Dis/No. Drawing:

1:1

A

RCHI

V

IO

 CA

D:

-

-

-

-

-

Firma/Sign.

Data/Date

Descrizione/Description

Rev.

-

Firma/Signature:

Data/Date:

Materiale/Material:

Descrizione/Description:

AERAULIQA SRL

Sede legale / Registered office: via Corsica 10, 25125 Brescia

Sede operativa / Warehouse-offices: 

via M.Calderara 39/41, 25018 Montichiari(BS)

Tel: +39 030 674681 Fax: +39 030 6872149

C.F. e P.IVA 03369930981 - REA BS-528635

www.aerauliqa.it

Questo documento è protetto dalle leggi vigenti in materia di privacy e copyright. Nè è vietata la copia, la diffusione senza

autorizzazione di Aerauliqa srl

disclosed without the specific written consent of Aerauliqa srl. All right are reserved.

T:

\A

rc

hiv

io

 P

ro

ge

tti 

In

du

st

ria

le

\In

-L

in

e_

B

ox

\d

ef

in

iti

vo\

Q

B

ox

-d150x

150\

VED DIS

AQD.00328.00

CASSONETTO DI ESTRAZIONE CENTRIFUGO

31/05/2016

NELSON JAMES K.

PBX00001

A

PBX00000

100
125
150

Codice

Descrizione

A

PBX00002

QBX100

A

QBX125
QBX150

 122 

 125 

 247 

 = 

 = 

 = 

 606 

 = 

 452 

 = 

 = 

 = 

 416 

 384 

 = 

 370 

416

384

370

Summary of Contents for QBX

Page 1: ...i tipo di anomalia nel funzionamento scollegare l apparecchio dalla rete elettrica e rivolgersi al più presto a personale qualificato In caso di riparazione richiedere esclusivamente ricambi originali L impianto elettrico a cui e collegato il prodotto deve essere conforme alle normative vigenti Prima di collegare il prodotto alla rete di alimentazione o alla presa elettrica accertarsi che i dati di...

Page 2: ...rno 1 10V di un sistema domotico BMS Schema di collegamento Fig 6D Configurazione dip switch 0110 Fig 6F Funzionamento a 3 velocità tramite selettore SEL 3V accessorio su richiesta L unità funziona alla velocità stabilita ruotando la manopola selettore SEL 3V accessorio di fig 8 La velocità 1 viene stabilita agendo sul trimmer V1 interno alla scatola morsettiera La velocità 2 viene stabilita agend...

Page 3: ...nd contact a qualified technician immediately Use original spare parts only for repairs The electrical system to which the device is connected must comply with regulations Before connecting the product to the power supply or the power outlet ensure that the data plate voltage and frequency correspond to those of the electrical mains the electrical power supply socket is adequate for maximum device...

Page 4: ...tion with CTRL M remote manual controller accessory on request The unit runs at the speed set by turning the knob of the 149 SEN CTRLM remote manual control panel accessory fig 7 Wiring diagram Fig 6C Dip switch configuration 0100 Fig 6F Variable speed operation through external domotic BMS system or ballast potentiometer The unit runs at the speed set by turning the knob of an external 1 10V ball...

Page 5: ...5 MONTAGGIO MOUNTING 3A 2A 4A 1B 3B 2B 4B 1A ...

Page 6: ...t be earthed 3 1 2 L N 5B Funzionamento tre velocità Three speed operation L N 5A Funzionamento singola velocità Vmax Single speed operation Vmax SEL 3V QBX AC 3V 1 2 3 4 S 1 S 2 S 3 G N D GND POT 10 N L V2 V1 6A QBX EC QBX EC PLUS Funzionamento velocità singola Single speed operation QBX AC 3V ...

Page 7: ...V2 GND POT 10 6B QBX EC QBX EC PLUS Funzionamento a due velocità Two speed operation S 1 S 2 S 3 G N D 1 2 3 4 GND POT 10 N L V1 V2 CTRL M N L 6C QBX EC QBX EC PLUS Funzionamento a velocità variabile tramite controllo esterno manuale CTRL M Variable speed operation with CTRL M remote manual controller ...

Page 8: ...ico esterno BMS o potenziometro ballast Variable speed operation through external domotic BMS system or ballast potentiometer 1 2 3 4 S 1 S 2 S 3 G N D N L V1 V2 THREE POSITION SWITCH INTERRUTTORE 3 POSIZIONI GND POT 10 6E QBX EC QBX EC PLUS Funzionamento a 3 velocità tramite selettore SEL 3V Three speed operation with SEL 3V speed selector ...

Page 9: ...ariabile tramite sistema domotico esterno BMS o potenziometro ballast Variable speed throught external domotic BMS system or ballast potentiometer 1 0 0 0 3 velocità tramite comando esterno SEL 3V Three speed with SEL 3V 1 0 Dip switch SETTAGGIO VELOCITA SETTING FAN SPEED 0 75 150 225 300 375 450 0 50 100 150 200 250 300 Static Pressure Pa Air flow m3 h Static Pressure Pa Air flow m3 h Position W ...

Page 10: ...ax Vmin 48 303 Vmed 51 351 Vmax 63 406 Static Pressure Pa Air flow m3 h QBX125 1EC Static Pressure Pa Air flow m3 h QBX150 1EC Position W max m3 h max A min 3 88 3 B 3 8 113 C 7 1 180 D 12 7 230 E 18 2 263 F 25 4 295 G max 31 2 312 A B C D E F G TRIMMER V1 V2 Position W max m3 h max A min 4 1 113 B 5 140 6 C 12 2 228 5 D 15 6 260 E 22 293 F 32 330 G max 41 2 360 A B C D E F G TRIMMER V1 V2 QBX150 ...

Page 11: ... QBX150 1EC PLUS Position W max m3 h max A min 6 8 149 B 9 3 189 C 21 7 284 D 40 7 365 E 69 5 442 F 82 3 460 G max 83 9 469 A B C D E F G TRIMMER V1 V2 Position W max m3 h max A min 6 7 174 B 9 1 218 C 43 5 351 D 73 442 E 77 510 F 80 1 540 G max 82 9 566 A B C D E F G TRIMMER V1 V2 A B C D E F G Static Pressure Pa Air flow m3 h QBX200 1EC PLUS Position W max m3 h max A min 7 211 B 12 285 C 39 477 ...

Page 12: ...x definitivo QBox d150x150 VED DIS AQD 00328 00 CASSONETTO DI ESTRAZIONE CENTRIFUGO 31 05 2016 NELSON JAMES K PBX00001 A PBX00000 100 125 150 Codice Descrizione A PBX00002 QBX100 A QBX125 QBX150 122 125 247 606 A 452 416 384 370 606 452 era a q i l a u This document is protected by privacy and copyright laws No part of this document may be reproduced adapted trasmitted or Peso Weight Scala Scale C...

Page 13: ... Trafilamento esterno massimo Maximum external leakage rate 2 p1 Tasso di miscela interno Internal mixing rate N A p2 Tasso di miscela esterno External mixing rate N A q Segnale avvertimento filtro Visual filter warning N A r Istruzioni installazione griglie Instructions to install regulated grilles vedere libretto istruzioni check the instruction booklet s Indirizzo Internet istruzioni di preasse...

Page 14: ...nominale Nominal external pressure Pa 250 275 l Caduta di pressione interna dei componenti della ventila zione Internal pressure drop of ventilation components Pa 20 10 m Caduta di pressione interna componenti estranei alla ventilazione Internal pressure drop of non ventilation components Pa N A N A n Efficienza statica ventilatori usati reg 327 2011 Static efficiency of fans used reg 327 2011 30 ...

Page 15: ...2 Trafilamento esterno massimo Maximum external leakage rate 2 p1 Tasso di miscela interno Internal mixing rate N A p2 Tasso di miscela esterno External mixing rate N A q Segnale avvertimento filtro Visual filter warning N A r Istruzioni installazione griglie Instructions to install regulated grilles vedere libretto istruzioni check the instruction booklet s Indirizzo Internet istruzioni di preass...

Page 16: ...2 Trafilamento esterno massimo Maximum external leakage rate 2 p1 Tasso di miscela interno Internal mixing rate N A p2 Tasso di miscela esterno External mixing rate N A q Segnale avvertimento filtro Visual filter warning N A r Istruzioni installazione griglie Instructions to install regulated grilles vedere libretto istruzioni check the instruction booklet s Indirizzo Internet istruzioni di preass...

Page 17: ...sterna nominale Nominal external pressure Pa 475 415 l Caduta di pressione interna dei componenti della ventila zione Internal pressure drop of ventilation components Pa 40 30 m Caduta di pressione interna componenti estranei alla ventilazione Internal pressure drop of non ventilation components Pa N A N A n Efficienza statica ventilatori usati reg 327 2011 Static efficiency of fans used reg 327 2...

Page 18: ...terna nominale Nominal external pressure Pa 415 500 l Caduta di pressione interna dei componenti della ventila zione Internal pressure drop of ventilation components Pa 30 25 m Caduta di pressione interna componenti estranei alla ventilazione Internal pressure drop of non ventilation components Pa N A N A n Efficienza statica ventilatori usati reg 327 2011 Static efficiency of fans used reg 327 20...

Page 19: ...19 NOTES ...

Page 20: ...VA VAT 03369930981 REA BS 528635 Tel 39 030 674681 Fax 39 030 6872149 www aerauliqa it info aerauliqa it Aerauliqa srl si riserva il diritto di modificare apportare migliorie ai prodotti in qualsiasi momento e senza preavviso Aerauliqa srl reserves the right to modify make improvements to products at any time and without prior notice 000704 02 0217 ...

Reviews: