Descaling the reservoir

Assuming the device is not used exclusively with 

distilled water, it must be descaled at regular 

intervals. The relevant intervals depend on the 

hardness of the water used and the frequency 

of use. If your tap water is particularly hard, the 

device should be regularly descaled, after it has 

been filled 10 – 15 times.

To ensure the operational safety of the device, it is 

particularly important to descale the water heater 

when signs of calcification become apparent (long 

warm-up time, reduced steam pressure).

•  Switch off the device, unplug from the mains 

and allow the device to cool down thoroughly..

•  Once the device has cooled down and the 

excess steam has been released, open the 

safety catch and empty the entire contents of the 

water heater.

•  Subsequently fill the water heater with a mixture 

of 100 ml vinegar and 300 ml water and let the 

descaling solution act for approx. 8 hours.

•  CAUTION! The steam cleaner must not be 

used, when it contains descaling solution! Do 

not replace the safety catch of the water heater 

during the descaling process. 

•  Once sufficient active time has elapsed, empty 

out the descaling solution from the water heater. 

To do so, turn the device over so that the 

descaling solution can run out of it.

•  To remove the remainder of the descaling 

solution, the water heater must subsequently 

be rinsed out 2 to 3 times with clean water, 

whereupon it may be reused again.

Care of accessories

•  Allow all accessories to dry thoroughly after use 

and before stowing them away..

•  Do not allow brush attachments to rest on their 

bristles after they have cooled and dried, since 

the pressure could deform them.

Care of the floor cloth

To guarantee the cleaning power and longevity of 

the microfiber cloth, please adhere to the following 

guidelines:

•  Wash and dry new microfiber cloths before 

using for the first time.

•  Clean the microfiber cloth at a temperature of 

60°C in the washing machine.

•  Do not wash the microfiber cloth together with 

clothes that fuzz easily, since such fibers may 

be caught up in the cloth and subsequently 

deposited on surfaces where it is used for 

cleaning.

•  The cleaning agent use should preferably 

be liquid, since the granules of dry cleaning 

material do not always dissolve and may remain 

within the cloth. This could result in scratches 

and stripes on the surface being cleaned when 

next in use.

•  Be careful to ensure that the cleaning agent 

used contains no bleaching agent, since this can 

attack the microfiber texture.

•  When cleaning the microfiber cloth, do not use 

any fabric softener, since this adversely affects 

the protective and humidity-absorption qualities 

of the microfiber texture.

•  To ensure the fibers are not damaged by high 

temperatures, the microfiber cloth should not be 

dried in a tumble drier.

HOW TO USE

Handling textiles

•  Before treating textiles, upholstery or carpets 

with the device, you should always conduct a 

test to check the tolerance of the material to the 

heating and steam treatment.

•  To do so, carefully apply steam to an 

inconspicuous area of the material to be treated 

and subsequently allow this to dry. Then check 

whether the colour or shape of the material 

have been affected by the treatment. 

30777-English_2 .indd   23

27/2/07   9:28:48 AM

Summary of Contents for ZQ 032

Page 1: ...15 GB Steam cleaner Instruction manual Model ZQ 032 30777 English_2 indd 15 27 2 07 9 28 46 AM ...

Page 2: ...bserve all instructions when using the device Please keep this instruction manual in a safe place for future reference When this device is passed on to another person please also supply this instruction manual with the device IMPORTANT SAFETY INSTRUCTIONS 17 DEVICE OVERVIEW 19 OPERATING THE DEVICE 19 USE OF ACCESSORIES 21 CARE AND MAINTENANCE 22 HOW TO USE 24 TECHNICAL DATA 24 ADVICE ON DISPOSAL 2...

Page 3: ...r heater Before filling or refilling the device always switch it off and unplug from the mains supply Before opening the safety catch the steam pressure within the device must be reduced and the device be allowed to cool for at least 15 minutes If the device remains very hot there is the risk of water spraying back out when it is filled Always be careful when opening the safety catch since a lefto...

Page 4: ...y after use and before stowing them away When storing wind the cord loosely around the device Be careful when doing so to ensure the cord is not exposed to excess tension Always store the device indoors in a cool dry and well ventilated location Repairs Never use the device when there is any sign of damage when it has fallen down or fails to work perfectly Regularly check the device power cord as ...

Page 5: ...unplug from the mains supply Subsequently the steam pressure present in the device must be reduced To do so press the steam control on the handle until the remaining steam has escaped Before opening the safety catch the steam pressure within the device must be reduced and the device be allowed to cool for at least 15 minutes If the device remains very hot there is the risk of water spraying back o...

Page 6: ...ted i e place the floor wiper onto the surface to be treated and start the steam treatment by pressing the steam delivery button In order to maintain the operating temperature and the required steam pressure the device continues heating regularly during operation During this process the red heat indicator lamp lights up The maximum operating time for the device is 40 minutes When the amount of ste...

Page 7: ...The floor wiper is designed to clean heat and damp proof floor coverings including e g Cleaning of stone tiled and PVC floors Cleaning of sealed wooden and parquet flooring The floor wiper can be attached to the handle using the two extension pipes To connect the extension pipes together and with the handle press the adjustment knob so that both parts can be fitted together Insert the extension pi...

Page 8: ...be used to treat delicate surfaces CARE AND MAINTENANCE Rinsing out the water heater Deposits in the water heater mean this should be regularly rinsed out after it has been filled 10 15 times Switch off the device unplug from the mains and allow the device to cool down thoroughly Once the device has cooled down and the excess steam has been released open the safety catch and fill the water heater ...

Page 9: ...towing them away Do not allow brush attachments to rest on their bristles after they have cooled and dried since the pressure could deform them Care of the floor cloth To guarantee the cleaning power and longevity of the microfiber cloth please adhere to the following guidelines Wash and dry new microfiber cloths before using for the first time Clean the microfiber cloth at a temperature of 60 C i...

Page 10: ...do not expose the material to heat for too long Heating too strongly may cause softening of the material and affect the surface structure ADVICE ON DISPOSAL Electrical appliances should not be placed with household trash It has been specified by law that old appliances must be disposed of via public community collection centres or bulky waste collection This is the only way to ensure that old appl...

Page 11: ...e g over voltage lightning Commercial use of the device Your statutory rights in the case of any deficiency in the device subsequent delivery cancellation deterioration compensation and so on in accordance with 437 BGB will remain unaffected by this guarantee Please retain the original packaging in case the product needs to be returned for repair Repaired or exchanged components are generally cove...

Page 12: ...30777 English_2 indd 26 27 2 07 9 28 48 AM ...