background image

View the expanded manual:

http://aeotec.com/support

Aeotec by Aeon Labs Recessed Door 

Sensor Gen5.

From Aeotec by Aeon Labs' intelligence series 

and our Gen5 range, comes Recessed Door 

Sensor. Invisibly installed, it sits within a door 

and its frame to provide all the information 

needed by a Z-Wave

®

 system for security, 

safety and ambiance without altering a room's 

aesthetics.

Familiarize yourself with your 

Recessed Door Sensor Gen5.

Your Recessed Door Sensor is comprised 

of two parts: the larger Main Sensor and the 

smaller Magnetic Sensor.

The larger Main Sensor

Main

 

Sensor

LED

Screw  Hole

Z-Wave Button  Hole

Screw  Hole

The Magnetic Sensor

Magnetic

 

Sensor

A magnet  in the plastic shell

The installation of your Recessed Door Sensor 

has two key steps:

1. Install both parts of your sensor.

2. Connect your sensor to your Z-Wave network.

Quick start.

1. Using a slot-head screw driver, remove the 

Main Sensor's lid by pressing gently against its 

exposed connector.

Prepare the Main Sensor.

2.Separate the Main Sensor's two sections 

by first removing its lid and then removing its 

internal components.

3.Remove the clear battery insulator by pulling 

it away from the Main Sensor.

4.With the battery insulator removed, reinsert 

the internal components into the Main Sensor's 

enclosure before reattaching its lid. Ensure that 

the Main Sensor's button aligns with the button 

hole of its lid. The Main Sensor will now look as 

it did prior to step 1.

With the Main Sensor powered and activated, it 

is now time to inlay it within your selected door 

frame.

The rectangular areas highlighted above are 

optimal installation positions.

Before beginning it is important to select a 

suitable position for your Recessed Door 

Sensor. For optimal performance, your sensor 

should be:
1. Either installed at the top of a door or the 

side of a door.

2. Positioned away from metal that could 

interfere with its magnetic functionality. This 

includes your door's plate, handle or lock 

mechanism.

3. Installed in a suitable location to ensure a 

clear (between 1mm and 5mm) separation 

when the door is closed.

4. Positioned exactly above or beside the 

position in which the Magnetic Sensor will be 

inlayed.

Install your Recessed Door Sensor.

Top of the door

Side  of the door

Prepare a space for the Main Sensor by drilling 

a hole into your doorframe using a 19mm wide 

drill bit. The hole should be 65mm deep.

Drill a corresponding hole in your door. The 

hole should be 15mm deep. As stated, the 

position of this hole should align exactly with 

the hole you just created in the doorframe. 

Again, use a 19mm wide drill bit.

Step 1

Step 2

65mm deep

19mm

Drill bit

Doorframe

15mm deep

19mm

Dril l bit

Door

With your door and doorframe prepared and 

the drill holes created, it's now time to mount 

both parts of your Recessed Door Sensor.

Insert the Main Sensor into the hole you created 

in the door frame then secure it using two screws.

Place a small amount of white glue (PVA) 

inside the hole you created for the Magnetic 

Sensor. Then place the sensor over and into 

the hole. Next, insert it by tapping gently on it 

with a rubber hammer.

Step 3

Step 4

Tap with

 

hammer

Done

Done

Secure  with screws

With your Recessed Door Sensor installed 

within a door and its frame, it's time to add 

it to your Z-Wave network. The following 

instructions tell you how to do this using 

Aeotec's Z-Stick and Minimote controllers. If 

you are using other products as your main 

Z-Wave controller, please refer to the part of 

their respective manuals that tell you how to 

add new devices to your network.

The gap between the two parts of your sensor 

must be no less than 1mm and no more than 

5mm. If your gap is different, re-affix the Main 

Sensor by altering its hole.

Step 5

Magnetic

Sensor

Main Sensor

1mm

Magnetic

Sensor

Main Sensor

Add your sensor to your Z-Wave network.

If you’re using a Z-Stick:

Action Button

1. If your Z-Stick is plugged into a gateway or a 

    computer, unplug it.

2. Take your Z-Stick to the door in which your 

    Recessed Door Sensor has been installed.

3. Press the Action Button on your Z-Stick.

4. Press the Z-Wave Button on your sensor with 

    a small pin or toothpick.

5. If your Recessed Door Sensor had been   

    successfully linked to your network, its LED 

    light will remain illuminated for 10 minutes. If 

    the linking was unsuccessful, its LED light 

    will blink for 3 seconds before turning off.

6. Press the Action Button on the Z-Stick to take 

    it out of installation mode.

If you’re using a Minimote:

Include

1. Take your Minimote to the door in which your 

    Recessed Door Sensor has been installed.

2. Press the Include button on your Minimote.

3. Press the Z-Wave Button on your sensor 

    with a small pin or toothpick.

4. If your Recessed Door Sensor had been 

    successfully linked to your network, its LED 

    light will remain illuminated for 10 minutes. If 

    the linking was unsuccessful, its LED light 

    will blink for 3 seconds before turning off.

5. Press any button on your Minimote to take it 

    out of installation mode. 

Advanced.

Remove your sensor from your Z-Wave 

network.

Your Recessed Door Sensor can be removed 

from your Z-Wave network at any time. You'll 

need to use your Z-Wave network's main 

controller to do this. The following instructions 

tell you how to do this using Aeotec by Aeon 

Labs' Z-Stick and Minimote controllers. If you 

are using other products as your main Z-Wave 

controller, please refer to the part of their 

respective manuals that tell you how to remove 

devices from your network.