5. You can test if your TriSensor has been successfully included into your Z-Wave network by pressing its Action
Button. If you press the button and your sensor's purple

 

LED is solid for a few seconds, then inclusion has been

successful. If the yellow LED is solid when the button is pressed, the inclusion has been unsuccessful and you should
repeat the steps from step 1.
 
6. Press the Action Button on the Z-Stick to return it to inclusion mode.
 
Return it to your gateway or computer.
 
If you're using a specific Z-Wave gateway you may need to refer to its user manual before proceeding:
 
7. Set your Z-Wave gateway or software to accept the Z-Stick as a Z-Wave Controller. Using your gateway or software,
re-scan for new products if required, if it is not, the new devices recently added should automatically populate in your
gateway/software interface.
 

If you're using an existing gateway (ie. Vera, Smartthings, ISY994i ZW, Fibaro, etc):
 

You may need to refer to your gateway's method of including devices if you do not know how to pair a Z-Wave device.
 
1. Put your primary Z-Wave gateway into pair mode, your Z-Wave gateway should confirm that it is waiting to add a
new device
 
2. Press the Action Button on your TriSensor. The LED on TriSensor will blink white, then become a solid yellow LED,
followed by a 2 flashes of white then green

 

LED to indicate a successful inclusion. If the pairing process has failed, the

LED will deactivate without flashing white or green.
 
3. You can test if your TriSensor has been successfully included into your Z-Wave network by pressing its Action
Button. If you press the button and your sensor's purple

 

LED is solid for a few seconds, then inclusion has been

successful. If the yellow LED is solid when the button is pressed, the inclusion has been unsuccessful and you should
repeat the steps from step 1.
 
 

Choosing a Location for your TriSensor.

 
TriSensor can bring its intelligent readings to many locations of your home. Before deciding on a location, there are
some things you should first consider.
 
TriSensors motion sensor uses light and heat readings to determine motion; sudden light and heating changes can
impact the sensor's quality of motion readings. As such, your sensor should not be installed in areas of artificial
temperature change. Thus, when selecting a location, avoid placing it beside or near air conditioners, and heaters.
 
Your TriSensor will be powered by batteries, you should avoid installing it in a location where the temperature can drop
below 0°C / 32°F - this is below the any battery operational use point. Selecting a location for your sensor also depends
on the layout of any area that you want monitored. Whatever the room or area, please ensure that it fits with your
sensor's effective motion sensing range as described in the following diagrams.
 
For optimal performance, your TriSensor should NOT be mounted directly on or near metal framing or other large
metallic objects. Large metal objects may weaken the Z-Wave wireless signal TriSensor depends on for communication
due to the wireless reflective properties of metal. 
 
TriSensor maximum motion detection range is: 23ft or 7m.
 

Outdoor installation.

Summary of Contents for TriSensor

Page 1: ...ps aeotec com z wave motion sensor To see whether TriSensor is known to be compatible with your Z Wave system or not please reference our Z Wave gateway comparison http aeotec com z wave gateways list...

Page 2: ...seconds Health Test Press and hold for 15 seconds Factory Reset Important safety information Please read this and other device guides carefully Failure to follow the recommendations set forth by Aeote...

Page 3: ...your TriSensor into a Z Wave Network With it powered on it s now time to add your TriSensor to a Z Wave network To pair TriSensor you are not limited to only the Z Stick or Minimote You may use any Z...

Page 4: ...ill deactivate without flashing white or green 3 You can test if your TriSensor has been successfully included into your Z Wave network by pressing its Action Button If you press the button and your s...

Page 5: ...eing false motion tracking run trial and error to determine the best sensitivity from a range of 0 11 by going down 1 sensitivity level after every test first 5 4 3 2 then 1 while setting Parameter 3...

Page 6: ...suggest you choose the second method using screws to affix the Back Mount Arm which would be more stable 2 After you have completed the affixing of Back Mount Arm you will need to lock TriSensor to t...

Page 7: ...placement is necessary Recommendation For networks which do not offer a method to display For the battery level of your TriSensor it is recommended that the sensor be tested occasionally to ensure tha...

Page 8: ...on 1 Remove TriSensors battery cover by unlocking then removing the cover 2 Press and hold TriSensors Action Button until LED turns yellow 5 seconds of holding 3 Release TriSensors button If you were...

Page 9: ...etwork Your TriSensor can be removed from your Z Wave network at anytime You ll need to use your Z Wave network s main controller to do this and the following instructions tell you how to do this usin...

Page 10: ...pdesk attachments 6064224662 Monitoring motion When TriSensor detects a motion event it will automatically send a notification report to Group 1 which is usually automatically set to report to your ga...

Page 11: ...gateways that use the older style of motion reports If you do not see status changes over your motion sensor you must enable this setting Command Class COMMAND_CLASS_SENSOR_BINARY Command SENSOR_BINA...

Page 12: ...or change to a Z Wave device based on the trigger Sometimes there may be delays if your gateway is already processing other data which can cause 1 2 second delays from time to time How many devices yo...

Page 13: ...leared DEFAULT SETTING 0 7 Temperature Alarm Setting Group 3 control This parameter is configured the threshold value that alarm level for temperature When the current ambient temperature value is lar...

Page 14: ...rature report Parameter SizeValueDescription 12 1 0 Disable Default 1 Red 2 Green 3 Blue 4 Yelllow 5 Pink 6 Cyan 7 Purple 8 Orange 13 Light report LED This setting changes the color of the LED when yo...

Page 15: ...0 US 1 0 1 1 Value and Description 0 Celcius 1 Fahrenheit 21 Temperature Threshold reporting Change threshold value for change in temperature to induce an automatic report for temperature sensor Scal...

Page 16: ...22 Light Threshold Report Change threshold value for change in light sensor to induce an automatic report for temperature sensor Scale Lux Parameter SizeValue Description 22 2 0 Disable Threshold Rep...

Page 17: ...92B29I https www amazon com HDE LX 1010B Digital Luxmeter Display dp B00992B29I This is purely an example the more accurate lux meter you have the better calibration setting you will be able to use 1...

Page 18: ...29 1 2019 TriSensor user guide Aeotec https aeotec freshdesk com support solutions articles 6000195459 trisensor user guide 18 18...

Reviews: