Notes for the wire connection ports:
N – Power input for neutral
L – Power input for live
IN – Input for load power supply
OUT1 – Output for load 1
OUT2 – Output for load 2
S1 – External switch control for load 1
S2 – External switch control for load 2

Inclusion/Exclusion

On factory default the device does not belong to any Z-Wave network. The device needs to be 

added to an existing wireless network

 to communicate with the

devices of this network. This process is called 

Inclusion

.

Devices can also be removed from a network. This process is called 

Exclusion

. Both processes are initiated by the primary controller of the Z-Wave network. This

controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is then performed doing a special manual action right on the device.

Inclusion

Press the action button two times for secure inclusion

Exclusion

Short press the Action button for exclusion

Product Usage

Click one time 1

 Send out a Node info without Security CC in command class list 

Quick press 2 times

 Send out a Node info that contains Security CC in the command 

Quick press 4 times

 Activate the automatic identification mode for external switch S1. The blue LED will fast blink to indicate the Nano Switch is in this mode.

Quick press 6 times

 Activate the automatic identification mode for external switch S1. The green LED will fast blink to indicate the Nano Switch is in this mode.

Quick trouble shooting

Here are a few hints for network installation if things dont work as expected.

Make sure a device is in factory reset state before including. In doubt exclude before include.

1. 

If inclusion still fails, check if both devices use the same frequency.

2. 

Remove all dead devices from associations. Otherwise you will see severe delays.

3. 

Never use sleeping battery devices without a central controller.

4. 

Dont poll FLIRS devices.

5. 

Make sure to have enough mains powered device to benefit from the meshing

6. 

Summary of Contents for AEOEZW140

Page 1: ...nd control on off of any wall switches In the event of power failure non volatile memory retains all programmed information relating to the unit s operating status It can connect to 2 external manual...

Page 2: ...hort press the Action button for exclusion Product Usage Click one time 1 Send out a Node info without Security CC in command class list Quick press 2 times Send out a Node info that contains Security...

Page 3: ...ch S2 should be identified successfully which means that the value of Configuration parameter 121 should be non zero then the Basic Set can be sent to the associated nodes in Group 3 via triggering th...

Page 4: ...light mode The LED will remain ON state Parameter 84 Set the ON OFF time of the LED when it is in Night light mode Set the ON OFF time of the LED when it is in Night light mode Size 1 Byte Default Va...

Page 5: ...e control destination for external switch Size 1 Byte Default Value 3 Setting Description 1 control the output loads of itself 2 control the other nodes 3 control the output loads of itself and other...

Page 6: ...uorescent Non Dimming IncandescentInductiveLEDMagnetic with without Dimming Switch Type Toggle Supported Notification Types Heat Alarm Firmware Updatable Updatable by Consumer by RF Supported Command...

Page 7: ...rk Exclusion is the process of removing Z Wave devices from the network Association is a control relationship between a controlling device and a controlled device Wakeup Notification is a special wire...

Reviews: