Wrench:
Lights up if mechanical tasks are ongoing
Antenna:
Displays the Radiator Thermostat network state.
Segment visible: rf-link established
Segment turnoff: rf-link lost
ID:
Lights up if the Display shows the Z-Wave NodeID
Battery
: Lights up if less than 15% battery is remaining
Lock:
Light up if child protection is set
Degree Celsius:
Displayed if the LCD shows a setpoint temperature
Setpoint adjustment.
The setpoint is adjusted by the plus ( + ) and minus ( - ) button.
Altering the setpoint locally will set the Radiator Thermostat to heating mode.
The energy-saving setpoint can only be adjusted via Z-Wave.
The configurable setpoint range is 8°C to 28°C.
If the setpoint is increased/decreased above/below the set point limits the Radiator Thermostat will change into
boost/off - mode.
Window open detection.
If the room temperature drops, window open detection will trigger.
Radiator Thermostat will change temporarily in off mode for 15 minutes.
Window open detection will end automatically after 15 minutes, then previously activity will restore.
Window open detection can be canceled by a button press.
Window open detection is disabled during the manufacturer-specific mode.
The sensitivity of the window open detection can be configured via parameter 7.