AeonAir WDH-945EL-1 User Manual Download Page 1

ITEM # 0526013

DEHUMIDIFIER

MODEL # WDH-945EL-1

ATTACH YOUR RECEIPT HERE

Serial Number__________   Purchase Date__________

Printed in China(P.R.C)

1

Questions, problems, missing parts? Before returning to your retailer, call our customer 

service department at 1-855-900-1298, Monday - Thursday, 8 a.m. - 6 p.m., EST, Friday, 8 

a.m. - 5 p.m., EST.

TM

AeonAir.com

TM

Summary of Contents for WDH-945EL-1

Page 1: ...Serial Number__________ Purchase Date__________ Printed in China P R C 1 Questions problems missing parts Before returning to your retailer call our customer service department at 1 855 900 1298 Mond...

Page 2: ...f you so desire Very Humid Recommended Setting Very Dry Very Humid V V Recommended Setting Very Dry V V RH 90 RH 30 RH 50 timer Before first use Before operating Operation Recommended Operating Temper...

Page 3: ...VXOW LQ ULVN RI UH HOHFWULF VKRFN DQG RU LQMXU WR SHUVRQV DVVRFLDWHG ZLWK WKH DSSOLDQFH KHFN ZLWK D TXDOL HG VHUYLFH UHSUHVHQWDWLYH LI LQ doubt that the appliance is properly grounded DO NOT USE PLUG...

Page 4: ...VLGH RU XSVLGH GRZQ DQG avoid shaking it 5 6 7 8 AeonAir com TM CAUTIONS 6 1 DO NOT pull on the power cord to avoid EUHDNDJH SRWHQWLDO GDQJHU RU LQMXU 2 127 XVH LQVHFW RLO SDLQW VSUD DURXQG WKH machi...

Page 5: ...aying the timer the display will to turn off automatically as per the below timer setting table This machine can automatically turn on off depending on your humidity RH setting Timer mode is to allow...

Page 6: ...removed from the machine by sliding it outward from the front of the unit and it should be emptied When the empty tank is replaced properly in the machine the unit will start up and run normally Fig...

Page 7: ...ve the drain cover at the rear of the unit Fig A 3 Remove the soft rubber stopper and place it in the water tank for safe keeping Fig B 4 Ensure the rubber seal ring is properly seated in the end of t...

Page 8: ...om any claim for damages to persons or property caused by the unit As some states do not allow the limitation or exclusion of incidental or consequential damages or do not allow limitation on implied...

Page 9: ...a unidad est apagada presione el bot n del TEMPORIZADOR para el encendido autom tico seg n la tabla de configuraci n del temporizador que se muestra a continuaci n 5 segundos despu s de mostrar el tem...

Page 10: ...enchufe con toma de tierra puede provocar riesgo de incendio GHVFDUJDV HOpFWULFDV R OHVLRQHV D SHUVRQDV DVRFLDGDV DO DSDUDWR RQVXOWH D XQ UHSUHVHQWDQWH SURIHVLRQDO GH VHUYLFLR WpFQLFR VL WLHQH GXGDV...

Page 11: ...UD HYLWDU TXH YLEUH 5 6 7 8 AeonAir com TM PRECAUCI N 20 1 Para evitar roturas da os potenciales o lesiones NO tire del cable de alimentaci n 2 NO utilice insecticidas aceite o pintura en HVSUD DOUHGH...

Page 12: ...30 al 90 de humedad relativa Diez segundos despu s de haber configurado la humedad la pantalla volver a mostrar la humedad de la habitaci n del momento El 30 es seco el 50 es normal y el 90 es m s hum...

Page 13: ...5 con el interruptor de seguridad Esta situaci n provoca la desconexi n inmediata del sistema del compresor y del motor del ventilador impidiendo que la unidad se condense NOTA Nunca manipule o intent...

Page 14: ...H WHULRU GH OD XQLGDG VpTXHOD FRPSOHWDPHQWH ALMACENAMIENTO Si no va a utilizar el deshumidificador durante prolongados per odos de tiempo siga estas instrucciones 1 Desconecte el cable de alimentaci...

Page 15: ...er da o consecuente ocasionado por el mal funcionamiento de la unidad y por la compra de la unidad el comprador acepta por la presente indemnizar y eximir al fabricante de cualquier reclamaci n por da...

Reviews: