background image

<1>Cautions

WJ-5000/5200 SERIES

WJ-5000/5200 SERIES

04

03

      Thank you for purchasing Stepless Electrical Co., Ltd., Dongguan City, 
the product, please read the installation instructions carefully before use and 
safekeeping.

 The installation instructions are not using quality assurance, to correct 

typographical errors  in  the  information the  fallacy  of  errata,  and  improved 
products, by the Electrical and Mechanical Services Ltd. of Dongguan City, 
stepless explanation at  any time, without prior notice, amendments will be 
incorporated Republication using the installation instructions.

01

Please ensure that the power supply and electrical outlet are in good contactand the earth wire 
must be firmly grounded!

Although  the average operating current of the chiller is small, but   theinstantaneous operating  current  could be up  to 6~10amps 
sometimes (Theinstantaneous operating current of models  of  AC110V power supply arepossible to be up to 10~15amps).

02

Please make sure there is stable and normal voltage for the working chiller!

As the refrigeration compressor is more sensitive to the power supply and voltage, so the operating voltage of our standard 
product  is  of  200~250V  (110V  model  is  of  100~130V).  If  you  do  need  a  wider  operating  voltage  range,customization  is 
available for us.

03

Unmatched power frequency can cause the chiller damage!

Please choose model of 50Hz or 60Hz according to actual circumstance.

04

To protect the pump, it’s strictly forbidden to run the chiller without water in the storage water tank! 

The new machine is packed after draining whole water in the tank, so please make sure the tank has water inside before  machine 
starting, otherwise it’s easily to have  the pump damaged. When the water level is below the green(NORMAL) range of the water level 
gauge,  the cooling  capacity of our chiller will go down slightly. Hence please  ensure the water level is within the green (NORMAL) 
range. To drain through circulating pump is strictly prohibited!

05

Please be sure that the air inlet and air outlet are in good ventilation!

There must be at least 30cm from obstructions to the air outlet which is in  the back of the cooler, and should leave at least 8cm 
between obstructions and the side air inlet.

06

The filter screen must be regularly cleaned!

It’s essential to unpick and wash the dust gauze, or the serious blockage will cause breakdown to the chiller.

07

Please pay attention to the effect of the condensate water!

With  greater  ambient  humidity,  when  the  water  temperature  is  lower  than  the  ambient  temperature,  the  condensate  water  will 
generate on the surface of water circular pipes and the cooled components. If above circumstance appears, it is recommended to set 
a higher water temperature or keep pipes and cooled parts warm.

Professional use only!

The appliance is not to be used by children or persons with reduced physical,sensory or mental capabilities, or lack 
of experience and knowledge, unless they have been given supervision or instruction, children being supervised not 

<2>

 

Parts introduction

TEMPERATURE CONTROLLER

FLOW ALAMR (RED)

NORMAL FLOW (GREEN)

POWER SWITCH

AIR INLET
(FILTER GAUZE)

WATER INJECTION PORT

POWER SOCKET(WITH FUSE)

ALARM OUTPUT TERMINAL

COOLING WATER OUTLET

COOLING WATER INLET

AIR OUTLET

WATER LEVEL GAUGE

OUTFALL

AIR OUTLET

OFFICIAL DISTRIBUTOR  UAB ELTECHNIKA 

WWW.AEONLASERS.LT | WWW.AEONLASERS.LV | WWW.AEONLASERS.EE

Summary of Contents for WJ-5000 Series

Page 1: ...SER MANUAL USER MANUAL 1 Cautions 2 Parts introduction 3 Installation 4 Operation and 5 Flow alarm and 6 Specifications 7 Simple troubleshooting CONTENTS parameters adjustment output ports 03 04 05 06...

Page 2: ...o please make sure the tank has water inside before machine starting otherwise it s easily to have the pump damaged When the water level is below the green NORMAL range of the water level gauge the co...

Page 3: ...te water again Please observe and record the current water level and inspect it again after the chiller running for a period of time if the water level drops obviously please re inspect the water pipe...

Page 4: ...ess key to change settings After modifying the value press the ENTER button RST to save and exit then new parameters take effect or press SET key SET to exit without saving parameters If there is no m...

Page 5: ...is 5 higher than normal and the alarm of over low water temperature will be on when water temperature is 10 lower than normal 2 Case 3 cooling water temperature is controlled by constant mode Requiri...

Page 6: ...on functions are optional 2 WJ 5200 Series compressional type chiller With heating and higher temperature precision functions are optional Model Voltage Frequency Current Compressor power Refrigeratio...

Page 7: ...olysis Poorventilationforairoutletandinlet Voltageis extremelylowor astable Improperparametersettingson thermostat Excessiveheatload Theworkingambienttemperatureis too highforthechiller Watertemperatu...