Configuration Value n(LSB) 

Parameter Number Definitions (8 bit): 

Parameter 

Number 

Hex/ 

Decimal 

Description 

Default Value 

Size 

0x02 (2)  

Enable/disable wake up for 10 minutes state when re-power on the 

Sensor  

0 = Disable, 

1 = Enable. 

0x08 (8) 

Set the timeout to go into the sleep state after the Wake Up 

Notification was sent out. 

[15, 255] 

30 

0x09 (9) 

Get the current power mode 

Value 1: 0 = USB power, 1 = Battery power. 

Value 2: 0 = Sleeping mode after re-power on, 1 = keep awake for 10 

minutes after re-power on, 2 = always awake state. 

Note: This parameter is a Get-only parameter. 

0x0A (10) 

Set the alarm time for the Buzzer when the sensor is triggered. 

Value 1: the time of Buzzer keeping OFF state (MSB) 

Value 2: the time of Buzzer keeping OFF state (LSB) 

Value 3: the time of Buzzer keeping ON state (MSB) 

Value 4: repeated cycle of Buzzer alarm. 

Note: one cycle is equal to the Buzzer from ON state to OFF state. 

0x001E0A0A 

0x27 (39) 

Set the low battery value. 

Range: 10% to 50%. 

20 

0x30 (48) 

Enable/disable the sensor report 

Bit =0, the corresponding sensor report is disabled. 

Bit =1, the corresponding sensor report is enabled. 

0x31 (49) 

Set the upper limit value (overheat). 

Value 1: temperature value (MSB) 

Value 2: temperature value (LSB) 

Value 2: 0 = Celsius unit, 1 = Fahrenheit unit. 

Value 4: reserved. 

US version: 

0x04100100 (104

). 

Other versions: 

0x01900000 (40

). 

0x32 (50) 

Set the lower limit value (under heat). 

Value 1: temperature value (MSB) 

Value 2: temperature value (LSB) 

Value 2: 0 = Celsius unit, 1 = Fahrenheit unit. 

Value 4: reserved. 

US version: 

0x01400100 (32

). 

Other versions: 

0x00000000 (0

). 

0x39 (57) 

Set the recover limit value of temperature sensor. 

Note: 

1.

 

When the current measurement 

<=

 (Upper limit – Recover limit), 

the upper limit report is enabled and then it would send out a 

sensor report when the next measurement is more than the 

upper limit. After that the upper limit report would be disabled 

again until the measurement 

<=

 (Upper limit – Recover limit). 

US version: 

0x1401(2.0

Other version: 

0x1400 (2.0

Summary of Contents for Aeotec Water Sensor 6

Page 1: ...Page 1 Aeon Labs Water Sensor 6 Z Wave Water Sensor...

Page 2: ...Page 2 Change history Revision Date Change Description 1 01 05 2017 Initial draft 2 03 28 2017 Update 3 04 07 2017 Update 4 04 27 2017 Update...

Page 3: ...mware upgrade As soon as Water Sensor 6 is removed from a Z Wave network it will be restored into default factory setting 1 Library and Command Classes 1 1 SDK 6 51 09 1 2 Library Basic Device Class B...

Page 4: ...TION_V1 COMMAND_CLASS_MULTI_CHANNEL_V4 COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATI ON_V3 COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2 2 Technical Specifications Operating distance Up to 492feet 150 meters outdoors 3...

Page 5: ...slowly when you short press the Action Button 2 Let the primary controller into inclusion mode If you don t know how to do this refer to its manual 3 Press the Action Button 4 If the inclusion is succ...

Page 6: ...VEPLUS_NODE Installer Icon Type 0x0C07 ICON_TYPE_SPECIFIC_SENSOR_NOTIFICATION_HOME_SECURITY User Icon Type 0x0C07 ICON_TYPE_SPECIFIC_SENSOR_NOTIFICATION_HOME_SECURITY 5 3 Manufacturer Specific Report...

Page 7: ...C 28 4C 65 61 6B 20 50 72 6F 62 65 20 32 29 5 5 2 Association Group Info Report Group Profile Vg1 Group 1 General Lifeline 01 01 00 00 01 00 00 00 Group 2 General NA 01 02 00 00 00 00 00 00 Group 3 No...

Page 8: ...ed report to the associated nodes in association Group 3 when the sensor probe 1 is triggered 2 Multi Channel endpoint 2 capability 71 COMMAND_CLASS_NOTIFICATION 5E COMMAND_CLASS_ZWAVEPLUS_INFO 59 COM...

Page 9: ...to OFF state 0x001E0A0A 4 0x27 39 Set the low battery value Range 10 to 50 20 1 0x30 48 Enable disable the sensor report Bit 0 the corresponding sensor report is disabled Bit 1 the corresponding sens...

Page 10: ...86 Enable disable the buzzer 0 disable 1 enable 1 1 0x57 87 To set which sensor is triggered the buzzer will alarm 1 If the Water leak is triggered the buzzer will alarm 2 If the vibration is trigger...

Page 11: ...sensor probes status through this configuration value If Bit 0 0 which means absence of water is triggered by probe 1 If Bit 0 1 which means presence of water is triggered by probe 1 If Bit 1 0 which...

Page 12: ...ult setting N A 1 Parameter number equals 0x30 Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 _ _ Notification Report for Overheat alarm Notification Report for Under heat alarm _ Configuration Repor...