Nano Dimmer user guide. : Aeotec by Aeon Labs
Page 11 sur 11
https://aeotec.freshdesk.com/support/solutions/articles/6000162176-nano-dimmer-user-guide-
energy monitoring are the Meter Command Class. Automatic reports are sent to association group 1,
which is setup via the Association Command Class.) Please consult the operation manual for these
control points for specific instructions on monitoring the Nano Dimmer.
Security or Non-security feature of your Nano Dimmer in Z-Wave network.
Including Nano Dimmer as a non-secure device:
If you want your Nano Dimmer as a non-secure device in your Z-Wave network, press the Action Button once on
Nano Dimmer when you pair it to your gateway. If inclusion is successful, the green LED will be on for 2 seconds, and
then return to a solid indication. If inclusion is unsuccessful, the red LED will be on for 2 seconds and then return to a
colourful gradient.
Including Nano Dimmer as a secure device:
In order to take full advantage of the Nano Dimmer, you will want your Nano Dimmer as a security device that uses
encrypted messages to communicate in your Z-wave network. A security enabled controller/gateway (or Z-Wave Plus
controller) is required.
1.
Set your Z-Wave Plus controller into pairing mode.
2.
Press the Action Button 2 times within 1 second on the Nano Dimmer, the blue LED (secure indication) will blink
to indicate the Nano Dimmer is entering into secure pairing mode.
3.
If the Nano Dimmer has been successfully added to your Z-Wave network, its RGB LED will be solid. If the
pairing was unsuccessful, the red LED will be on for 2 seconds and then remain a colourful gradient, repeat the
instructions above from step 1.
Reset your Nano Dimmer.
If at some stage, your primary controller is missing or inoperable, you may wish to reset all of your Nano Dimmer’s
settings to their factory defaults.
To do this, press and hold the Action Button for 20 seconds and then release it. Your Nano Dimmer will now be reset
to its original settings, and the green LED will be solid for 2 seconds and then remain the colourful gradient status as
a confirmation.
Warning.
1.
Install only in a UL listed junction box sized 3 2 2.75 inch (75 50 70 mm) or larger, minimum volume 14 in
3
(230
cm
3
).
2.
Use Copper Conductors Only.
3.
“CAUTION – Risk of Electric Shock – More than one disconnect switch may be required to de-energize the
equipment before servicing”.
4.
“WARNING - This device shall not be used in combination with a wall switch controlling a receptacle.”