AEO WP401209 User Manual Download Page 2

3)

 

[Connect to a Power Source]

 by connecting the DC Short Connector (3) 

to a proper DC power supply with an output of 12V to 24V.   

 

Section 4: CLEANING AND MAINTENANCE 

Periodically clean the water pump to prevent blockage. 

!  Caution  ! 

Handle  with  care  to  prevent  the  impeller  from  falling  out  and 

breaking  while  detaching  the  unit.  Disconnect  Water  Pump  from  Power 

before cleaning. 

 

 

1)

 

Pull the filter housing apart from the pump while squeezing the sides. 

2)

 

Press on the bottom board while sliding it in the direction of the arrow. 

3)

 

Turn the impeller cover counter-clockwise and then carefully pull it out. 

Impeller  maybe  attached  to  the  cover  or  stay  inside  the  pump.  Be 

aware of the white washers may fall out.   

4)

 

Separate  the  impeller  from  the  water  pump  or  detach  it  from  the 

impeller cover. 

5)

 

Wash every part including the inside of motor chamber and clean out 

the debris 

6)

 

Assemble  the  pump  in  reverse  sequence  then  put  water  pump  back 

under water, connect power to start running   

 

Section 5: TROUBLE-SHOOTING 

*

 Pump stopped running?

 

1)

 

Check power source: if connected to a Solar Panel, make sure it is 

fully  exposed  to  sunlight  and  is  not  covered  in  shade  or  dirt.   

Solar cells are connected in series, any shadow or tiny dirt on one 

cell could significantly compromise the power output.   

2)

 

Check  for  blockage:  clean  the  pump  as  described  in  Section  4: 

CLEANING AND MAINTENANCE.

 

*Pump is running, but there’s no water going through?   

1)

 

Check  for  blockage:  clean 

the  nozzle  tubes,  water  pump  outlet,

 

and filter to remove any debris.

 

 

 

 

 

 

 

Section 6: TECHNICAL DATA AND PUMP CURVE 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

**If this product is defective or damaged upon delivery, please contact our 

customer service by email 

[email protected]

 or   

call 

909-698-8199

 for help. Thank you! 

 

Operating voltage

 

DC 12V-24V 

Maximum pump head (Hmax) 

2.95ft @12V;   

7.85ft@24V 

Maximum flow rate (Qmax) 

124G/H@12V;   

196G/H@24V 

Dimensions 

4.17 x 1.85 x 1.97 inches 

Net weight 

0.99 lbs. 

Cable length 

16.4 ft 