16
Current Probes & Sensors for Power Quality Meters and Power Energy Loggers
4.4 Safety
Protection index IP 40 for the probes and IP 30 jaws open, according to IEC 60 529
■
IP 65 for the AmpFlex
®
according to IEC 60 529
■
IK 04 according to IEC 50102
Drop test: According to IEC 61010-1
Electrical safety according to IEC 61010-2-032.
Maximum applicable voltage:
AmpFlex
®
193-BK:
1000V CAT III; 600V CAT IV
AmpFlex
®
196A-BK: 1000V CAT IV
MiniFlex
®
-BK:
1000V CAT III; 600V CAT IV
J93-BK:
600V CAT III; 300V CAT IV
MN93 /MN193-BK:
600V CAT III; 300V CAT IV
MR193-BK:
600V CAT III; 300V CAT IV
SL261:
600V CAT III
SR193-BK:
1000V CAT III; 600V CAT IV
4.5 Conformity To International Standards
The instruments are compliant with IEC 61010-2-032: 300V in category IV or 600V
in category III. The equipment is protected by double or reinforced insulation
.
Type of current sensor per IEC 61010-2-032: type A
.
4.6 Electromagnetic Compatability
The instruments conform with standard IEC 61326-1.
Specifications are subject to change without notice.
Summary of Contents for SL261
Page 23: ...Notes...