RMS Clamp-on Simple Logger® Model CL600

APPENDIX A

Importing .TXT Files into a Spreadsheet

Opening a Simple Logger .TXT file in Excel

The following example used with Excel Ver. 7.0 or higher.

1. After  opening  the  Excel  program,  select 

“File”

  from  the  main

menu and then select 

“Open”

.

2. In  the  dialog  box  that  appears,  browse  and  open  the  folder

where  your  logger  .TXT  files  are  stored.  This  will  be  located

in 

C:\Program Files\Simple Logger 6.xx

 if you accepted the

default choice offered by the logger installation program.

3. Next, change the file type to 

“Text Files”

 in the field labeled 

Files

of Type

. All the .TXT files in the logger directory should now be

visible.

4. Double-click on the desired file to open the Text Import Wizard.
5. Review the selections in the first wizard screen and make sure

that the following choices are selected:

Original Data Type:  Delimited

Start Import at Row:  1

File Origin: 

Windows (ANSI)

6. Click the 

“NEXT”

 button at the bottom of the Wizard dialog box.

The second wizard screen will appear.

7. Click on 

“Comma”

 in the Delimiters box. A check mark should

appear.

8. Click the 

“NEXT” 

button at the bottom of the Wizard dialog box.

The third wizard screen will appear.

9. A view of the actual data to be imported should appear in the

lower section of the window. Column 1 should be highlighted. In

the Column Data Format window, select 

“Date”.

10. Next, click on 

“Finish”

 to complete the process and import the

data.

11. The data will now appear in your spreadsheet in two columns (A

and B) and will look similar to that shown in Figure A-1.

Summary of Contents for Simple Logger CL600

Page 1: ...SIMPLE LOGGER RMS CLAMP ON MODULE CL600 E N G L I S H User Manual...

Page 2: ...rument Please record this number and purchase date for your records RMS CURRENT CLAMP ON SIMPLE LOGGER MODEL CL600 CATALOG 2116 11 SERIAL _ _______________________________________________ PURCHASE DAT...

Page 3: ...ical Specifications 7 3 3 Environmental Specifications 7 3 4 Safety Specifications 7 4 OPERATION 8 4 1 Software Installation 8 4 1 Recording Data 9 4 3 Using the Software 10 5 MAINTENANCE 11 5 1 Batte...

Page 4: ...ument while connected to any circuit or input ALWAYS inspect the instrument and lead prior to use Replace any defective parts immediately NEVER use the Model CL600 on electrical conductors rated above...

Page 5: ...er and notify your distributor at once giving a detailed description of any damage Save the damaged packing container to substantiate your claim Do not use an instrument that appears to be damaged 1 3...

Page 6: ...S 232 Interface PRESS RS 232 LOGGER OPERATION 1 Press to Start Logging Logging Two Blinks 2 Press to Stop Logging Stand By One Blink 3 Press Hold 5 Seconds to Shut Off Off No Blinks Warning All Data w...

Page 7: ...D indicates the status of the logger Single Blink STAND BY mode Double Blink RECORD mode Continuously On OVERLOAD condition No Blinks OFF mode Warning Delete Data Pressing the PRESS button for more th...

Page 8: ...0 to 600A Resolution 8 Bit 0 5Arms Scale Range Maximum Input Resolution 100 600 Arms 4 Arms 50 500 Arms 2 Arms 25 250 Arms 1 Arms 12 5 125 Arms 0 5 Arms Sample Rate 4096 hr max decreases by 50 each ti...

Page 9: ...42mm 2 conductors 1 25 4mm each Case Material Polycarbonate UL V0 3 3 Environmental Specifications Operating Temperature 4 to 158 F 20 to 70 C Storage Temperature 4 to 176 F 20 to 80 C Relative Humidi...

Page 10: ...ored file One 9 pin serial port one parallel port for printer support CD ROM drive 1 Insert the Simple Logger CD into your CD ROM drive If auto run is enabled the Setup program will start automaticall...

Page 11: ...low the on screen prompts to install the software 4 1 Recording Data Position the Model CL600 around the conductor to be measured NOTE Be sure that the positioning of the CL600 allows the jaws to firm...

Page 12: ...ched you will need to select a language Select Port from the menu bar and select the Com port COM 1 2 3 or 4 you will be using see your computer manual Once the software automati cally detects the bau...

Page 13: ...ed screw 3 Locate the two wire red black battery connector and attach the 9V battery to it Make sure that you observe polarity by lining up the battery posts to the proper terminals on the connector 4...

Page 14: ...click on the desired file to open the Text Import Wizard 5 Review the selections in the first wizard screen and make sure that the following choices are selected Original Data Type Delimited Start Im...

Page 15: ...ick on column B at the top of the column to select the data then click on Insert from the main menu and select Columns from the drop down menu 2 Next click on column A at the top of the column to sele...

Page 16: ...e option from the category list on the left Select the time format you desire and click on OK to format the column Figure A 2 shows a typical spreadsheet with date time and value displayed It may be n...

Page 17: ...Includes calibration certificate plus recorded calibration data Ship To Chauvin Arnoux Inc d b a AEMC Instruments 15 Faraday Drive Dover NH 03820 USA Phone 800 945 2362 Ext 360 603 749 6434 Ext 360 F...

Page 18: ...you may return the in strument to us for repair provided we have your warranty registration in formation on file or a proof of purchase AEMC Instruments will at its option repair or replace the fault...

Page 19: ......

Page 20: ...08 18 99 MAN 100215 v13 Chauvin Arnoux Inc d b a AEMC Instruments 15 Faraday Drive Dover NH 03820 USA Phone 603 749 6434 Fax 603 742 2346 www aemc com...

Reviews: