Handscope Harmonic Analyzer Oscilloscope Model OX 5042B

PRODUCT PACKAGING (2150.21)

Handscope Oscilloscope 

Model OX 5042B 

Cat. #2150.21

(1) USB Cable + Driver 

Cat. #2135.41

(2) Probe 10:1 600 V BNC-M 

Cat. #5000.50

(1) US Wall Plug,  

Adapter 5 V 

Cat. #2153.78

(1) USB Drive 

(SX-METRO Software 

OX 5042B User Manual 

(1) Adapter Banana-F  

BNC-M 

Cat. #2118.46

(1) Set of two color-coded 

leads and clips 

Cat. #2140.63

(1) Black Tool Bag 

Cat. #2133.72

(1) Red Test Probe 

Cat. #5000.98  

(1) Black Test Probe 

Cat. #5000.97

OX 5022B / OX 5042B 

Cable - Replacement USB 

Charging Cable 

Cat. #5100.17

Also Included:

(1) Test Report
(1) Battery Information Sheet
(6) 1.2 V NiMH rechargeable batteries 2700 mA·h

Summary of Contents for OX 5042B

Page 1: ...Handscope Harmonic Analyzer Oscilloscope Model OX 5042B ENGLISH PORTABLE OSCILLOSCOPES WITH AEMC INSTRUMENTS Quick Start Guide ...

Page 2: ...742 2346 This documentation is provided as is without warranty of any kind express implied or otherwise Chauvin Arnoux Inc has made every reasonable effort to ensure that this documentation is accurate but does not warrant the accuracy or completeness of the text graphics or other information contained in this documentation Chauvin Arnoux Inc shall not be liable for any damages special indirect in...

Page 3: ...e of purchase or obtained by returning the instrument to our repair and calibration facility for a nominal charge The recommended calibration interval for this instrument is 12 months and begins on the date of receipt by the customer For recalibration please use our calibration services Refer to our repair and calibration section at www aemc com Serial Catalog 2150 21 2150 22 2150 23 Model OX 5042...

Page 4: ...apter 5 V Cat 2153 78 1 USB Drive SX METRO Software OX 5042B User Manual 1 Adapter Banana F BNC M Cat 2118 46 1 Set of two color coded leads and clips Cat 2140 63 1 Black Tool Bag Cat 2133 72 1 Red Test Probe Cat 5000 98 1 Black Test Probe Cat 5000 97 OX 5022B OX 5042B Cable Replacement USB Charging Cable Cat 5100 17 Also Included 1 Test Report 1 Battery Information Sheet 6 1 2 V NiMH rechargeable...

Page 5: ...ETRO Software OX 5042B User Manual 1 Adapter Banana F BNC M Cat 2118 46 1 Set of two color coded leads and clips Cat 2140 63 1 Carrying Case Cat 2155 77 1 Red Test Probe Cat 5000 98 1 Black Test Probe Cat 5000 97 OX 5022B OX 5042B Cable Replacement USB Charging Cable Cat 5100 17 Also Included 1 Test Report 1 Battery Information Sheet 6 1 2 V NiMH rechargeable batteries 2700 mA h 1 Current Probe MN...

Page 6: ...ETRO Software OX 5042B User Manual 1 Adapter Banana F BNC M Cat 2118 46 1 Set of two color coded leads and clips Cat 2140 63 1 Carrying Case Cat 2155 77 1 Red Test Probe Cat 5000 98 1 Black Test Probe Cat 5000 97 OX 5022B OX 5042B Cable Replacement USB Charging Cable Cat 5100 17 Also Included 1 Test Report 1 Battery Information Sheet 6 1 2 V NiMH rechargeable batteries 2700 mA h 1 Current Probe MN...

Page 7: ...nformation to acknowledge This product complies with the Low Voltage Electromagnetic Compatibility European directives 73 23 CEE 89 336 CEE Ground Earth The product has been declared recyclable In the European Union this product is subject to a separate collection system for recycling electrical and electronic components in accordance with directive WEEE 2002 96 EC Definition of Measurement Catego...

Page 8: ...ternal power supply must be connected to the instrument and to the network 98 to 264 VAC The power supply to the instrument is fitted with an automatically resettable electrical protection after disappearance of the fault As a safety measure only use factory supplied parts and accessories It is advised to use individual safety protection whenever the environmental situations in which the instrumen...

Page 9: ...the battery cover use a coin to turn the slot on the back of the unit counter clockwise Description The Handscope Oscilloscope Model OX5042B combines three instruments into one 40 MHz oscilloscope Independent 8000 ct multimeter with power measurements Built in harmonic analyzer out to the 31st harmonic fundamental between 40 and 450 Hz The instrument operates at a constant acquisition depth of 250...

Page 10: ...de authorized between the two channels is 600 V in CAT III Thus the operator the test systems and the environment are completely protected at all times Any voltage even dangerous on one channel will not be present on the other channel The low points of the inputs are completely insulated so there is no possibility of the low points looping which can be dangerous and highly destructive NOTE The use...

Page 11: ... Use these navigation buttons to the menus and dialog boxes VERTICAL Vertical movement and automatic selection in the secondary menus Adjustment of values in the main menus Vertical movement in a dialog box HORIZONTAL Horizontal movement through the main menus Adjustment of values in the secondary menus Horizontal movement in a dialog box ENTER Opens a dialog box from a main menu or a secondary me...

Page 12: ...an automatic adjustment on channels A and B The success of each vertical autoset conditions the activation of the channel Run Hold Starts or stops an acquisition CHARGE STATUS Battery Charge LED OPTICAL COMMUNICATOR Provides the communication between the oscilloscope and a PC TIME BASE BUTTONS Increases the time base for acquisition up to 200 s Decreases the time base for acquisition down to 25 ns...

Page 13: ...y capacitance between modes The noise of the digital ground earth is sent to the analog input by stray capacitance NOTE To prevent electric shocks or possible fires never use accessories on which the casing is accessible if it has a voltage of 30 VRMS compared to the ground 10 1 Probe Calibration For the best response you must adjust the probe s low frequency compensation NOTE To carry out this ad...

Page 14: ...nected to the probe Run an Autoset to carry out pre setting Adjust the sensitivity and vertical offset of the channel so that the signal fills the screen Adjust the time base to 200 µs to view a signal period on the screen Turn the BNC base of the probe in to access the probe adjustment screw In this example the probe is overcompensated so an overshoot occurs Turn the screw in either direction unt...

Page 15: ...ear intervals for recalibration or as required by other standards or internal procedures For instrument repair and calibration You must contact our Service Center for a Customer Service Authorization Number CSA Send an email to repair aemc com requesting a CSA you will be provided a CSA Form and other required paperwork along with the next steps to complete the request Then return the instrument a...

Page 16: ...C Instruments not by the distributor from whom it was purchased This warranty is void if the unit has been tampered with abused or if the defect is related to service not performed by AEMC Instruments Full warranty coverage and product registration is available on our website at www aemc com warranty html IMPORTANT WARRANTY NOTE By registering online within 30 days of the purchase date your warran...

Page 17: ...next steps to complete the request Then return the instrument along with the signed CSA Form Please write the CSA on the outside of the shipping container Return the instrument postage or shipment pre paid to Chauvin Arnoux Inc d b a AEMC Instruments 15 Faraday Drive Dover NH 03820 USA Phone 800 945 2362 Ext 360 603 749 6434 Ext 360 Fax 603 742 2346 E mail repair aemc com Caution To protect yourse...

Page 18: ...18 Handscope Harmonic Analyzer Oscilloscope Model OX 5042B NOTES ...

Page 19: ...Handscope Harmonic Analyzer Oscilloscope Model OX 5042B 19 NOTES ...

Page 20: ...AEMC Instruments 15 Faraday Drive Dover NH 03820 USA Phone 603 749 6434 800 343 1391 Fax 603 742 2346 www aemc com 03 23 99 MAN 100587 V00 Chauvin Arnoux Inc d b a AEMC Instruments All Rights Reserved ...

Reviews: