background image

 

ELECTRICAL SPECIFICATIONS

 

Nominal Range: 

150A

 

Measurement Range: 

0.1 to 150A 

Transformation Ratio: 

Voltage output

 

Output Signal: 

10mV/A 

Accuracy and Phase Shift*: 

Accuracy: 

0.1 to 1A: 

 3% Reading ± 200µV 

1 to 20A: 

 2% Reading ± 200µV 

20 to 80A: 

 1% Reading 

80 to 150A:  

 3% Reading 

150 to 200A: 

 7% Reading 

 

 

Phase Shift: 

0.1 to 1A: 

Not Specified 

1 to 20A: 

 3° 

20 to 80A: 

 2° 

80 to 150A:  

 3° 

150 to 200A: 

 4° 

(*Reference conditions: 18°C to 28°C, 20 to 75% 
RH, external magnetic field <40 A/m, 48 to 65 Hz 
sine wave, distortion factor less than 1%, no DC 
component, no external current carrying conductor, 
test sample centered.) 
Load impedance > 1 M

Frequency Range: 

40 to 10kHz

 

Limit Operating Conditions: 

200A permanently to 1kHz; 
Derating above 3kHz: 200A x (1/0.333F), F in kHz 

Crest Factor: 

3 @ 150A peak max with an error 
(due to CF) of 3% 

Overload: 

240A for 10 min ON, 30 min OFF

  

Working Voltage: 

600Vrms

 

Common Mode Voltage: 

600Vrms

 

Influence of Adjacent Conductor: 

< 15mA/A at 50 Hz 

Influence of DC on AC signal: 

DC Current < 10A, < 10% 

Influence of Conductor Position in Jaw:  

0.5% of mV output @ 50/60 Hz 

Influence of Frequency:  

40 Hz to 1 kHz: 5% of mV output 
1 kHz to 10 kHz: 15% of mV output 

Influence of Load:  

< 3% of mA output from 40 Hz to 1 kHz 
< 12% of mA output from 1 kHz to 10 kHz 

Influence of Temperature: 

 200 ppm/°K, or 0.2% of mV output per 10°K 

Influence of Humidity (10 - 90% RH): 

 0.2% of mV output per 10°K @ 18°C to 28°C 

MECHANICAL SPECIFICATIONS 

Operating Temperature: 

14° to 131°F (-10° to +55°C)  

Storage Temperature: 

-40° to 158°F  (-40° to +70°C) 

Operating Relative Humidity: 

10-35°C 85% RH 
(without roll-off above 35°C) 

Maximum Cable Diameter: 

One Ø 0.78” (20mm), bus bar 20 x 5mm 

Case Protection: 

IP 40 (IEC 529) 

Drop Test: 

Test per IEC 68-2-32: 
1.0m drop on 38 mm of Oak on concrete. 

Mechanical Shock: 

Test per IEC 68-2-27 

Vibration: 

Test per IEC 68-2-6 

Dimensions: 

5.47 x 2.00 x 1.18"  (139 x 51 x 30mm) 

Weight: 

180 g (6.5 oz) 

Polycarbonate Material: 

Jaws: Polycarbonate with 10% fiberglass charge, 
 

Red UL 94 V0 

Case: Polycarbonate 920A Gray 

Opening Operations - Life: 

> 50,000 

Output: 

MN352: 

Two standard safety banana jacks (4mm)  

MN353: 

Double/reinforced insulated 5 ft (1.5m) 

lead with safety 4mm banana plug  

SAFETY SPECIFICATIONS 

      

      

     

Electrical: 

Double insulation or reinforced insulation between 
the primary or secondary and the outer case of 
the handle conforms to IEC 1010-2-32. 

Common Mode Voltage: 

600V Category III 
Pollution Degree 2 

Dielectric Strength: 

5550 V, 50/60 Hz between primary, secondary  
and the outer case of the handle 

Electromagnetic Compatibility: 

EN 50081-1 Class B 
EN 50082-2 Electrostatic discharge 
   IEC 1000-4-2 
Radiated field IEC 1000-4-3 
Fast transients IEC 1000-4-4 
Magnetic field at 50/60 Hz IEC 1000-4-8 

ORDERING INFORMATION 

AC Current Probe MN352

 .......... 

Cat #2116.26 

AC Current Probe MN353

 .......... 

Cat #2116.27 

Both models include a user manual and a 
product warranty and registration card. 

Accessories: 

Leads, set of 2, 5 ft safety 
(1000V) for Model MN352 ............ 

Cat #2111.29 

Banana plug adapter 
(to non-recessed plug)  ................ 

Cat #1017.45 

 

E192383

2.56"

 (65 mm)

5.47"

 (139 mm)

.83"

 (21 mm)

Black

Red

.73"

2.00"

 (51 mm)

(18.5 mm)

.1.18"     

(30 mm)

Tactical

Barrier

(keep hands below

this barrier)

www.

ShopAEMC

.com

Shop for AEMC products online at:

1.877.766.5412

Reviews: