AEMC instruments Simple Logger AmpFlex AL24-2500 User Manual Download Page 7

Simple Logger

®

 AmpFlex

 Current Probes 

 

Features 

          

  

 

600 V CAT III

 

   

 !
!

"

BATTERY: 9 V, NEDA 1604, 6LF22, 6LR61

99 CHAUNCY STREET • BOSTON MA 02111, USA

(617) 451-0227 • Fax (617) 423-2952 • www.aemc.com

MADE IN USA

  

1. Press to Start Logging

(Logging = Two Blinks)

2. Press to Stop Logging

(Stand-By = One Blink)

3. Press & Hold 5sec. to Shut Off

(Off = No Blinks)

Warning: All Data will be Deleted!

#$%& ''

®

1

3

4

 

(1) Start/Stop Button

(2) Flexible Sensor Input

(3) Operation Mode Indicator

(4) RS-232 Interface

 

Indicators and Buttons 

The AmpFlex™ Logger has only one button and one indicator. Both are 
located on the front panel. 
The button is used to start and stop recordings and to turn the logger on 
and off. The red LED indicates the status of the logger; 

OFF, STANDBY

 

or 

RECORDING

. When the LED is lit continuously, it indicates an 

overload condition. 

 

Inputs and Outputs 

The top of the logger incorporates a 
permanent flexible sensor attached 
by a 5ft. lead. 

HI

LO

HI

LO

The bottom has a 5-pin circular 
connector used for serial data 
transmission from the logger to your 
computer. 

 

Range Selection 

Before operating, determine the 
maximum current to be logged. 
Remove the back cover and select 
the appropriate range as shown. 

 

 

Summary of Contents for Simple Logger AmpFlex AL24-2500

Page 1: ...Simple Logger AmpFlex Current Probes AL24 2500 AL36 2500 AL24 5000 AL36 5000 USER MANUAL...

Page 2: ...ument to us for repair provided we have your warranty registration information on file or a proof of purchase AEMC Instruments will at its option repair or replace the faulty material REGISTER ONLINE...

Page 3: ...Packaging 4 Specifications 4 Features 6 Indicators and Buttons 6 Inputs and Outputs 6 Range Selection 6 Battery Installation 7 Operation 7 Software 8 Minimum Computer Requirements 8 Installation 8 Us...

Page 4: ...the operator For maintenance use only original replacement parts NEVER open the back of the instrument while connected to any circuit or input ALWAYS inspect the instrument and leads prior to use Rep...

Page 5: ...ifications ELECTRICAL Number of Channels 1 Current Ranges 2 Input AL24 36 2500 250 2500 Arms internally selectable AL24 36 5000 500 5000 Arms internally selectable Input Connection Permanent Flexible...

Page 6: ...ure 4 to 158 F 20 to 70 C Storage Temperature 4 to 174 F 20 to 80 C Relative Humidity 5 to 95 non condensing MECHANICAL Size 2 1 2 x 1 9 16 x 4 1 2 63 5 x 40 64 x 114 3mm Maximum Conductor Size 24 len...

Page 7: ...AmpFlex Logger has only one button and one indicator Both are located on the front panel The button is used to start and stop recordings and to turn the logger on and off The red LED indicates the sta...

Page 8: ...ry into the holding clip on the circuit board 5 If the unit is not in record mode after installing the new battery disconnect it and press the button twice then reinstall the battery 6 Reattach the ba...

Page 9: ...CD ROM drive is assumed to be drive letter D If this is not the case substitute the appropriate drive letter Auto Run Enabled If Auto Run is enabled insert the Simple Logger CD into the CD ROM drive...

Page 10: ...will be using see your computer manual Once the software automatically detects the baud rate the logger will communicate with the computer ID number of the logger and number of points recorded displa...

Page 11: ...T includes calibration certificate plus recorded calibration data Chauvin Arnoux Inc d b a AEMC Instruments 15 Faraday Drive Dover NH 03820 USA Tel 800 945 2362 Ext 360 603 749 6434 Ext 360 Fax 603 7...

Page 12: ...Chauvin Arnoux Inc d b a AEMC Instruments 15 Faraday Drive Dover NH 03820 www aemc com 99 MAN 100208 v9 01 05...

Reviews: