![AEM RaceGrade RG EGT-8 Setup Manual Download Page 7](http://html1.mh-extra.com/html/aem/racegrade-rg-egt-8/racegrade-rg-egt-8_setup-manual_2860605007.webp)
SETUP GUIDE
This product is legal in California for racing vehicles only and should never be used on public
highways. AEM Performance Electronics, 2205 W. 126th Street Unit A, Hawthorne, CA 90250,
Phone: (310) 484-2322 Fax: (310) 484-0152
8. In the “
Setup Editor
” under the “
Outputs
” tab, check to make sure the channels you selected to import are
present. If they are not, go back to step 4 and try again.
9. Find the output “
TC1
” and check that the Primary Input is “
TC1_raw
”. If it is not, change it now. If setting up
“
TC2
” the input should be “
TC2_raw
” and so on.
10. The correct scalar should be automatically set when you imported the .aemcan file. If you want to use the
default scalar and not create a custom one, skip ahead to step 11. The software automatically creates one
scalar for each of the TC8’s channels when the .aemcan file is imported. If the selected scalars are not correct
for your application you may change the scalar to a custom one. To create a custom scalar, go to the
“
Scalars
” tab in the “
Setup Editor
” window. Select “
Insert
” and create a name for your new scalar. Once
named, enter the correct scalar value and offset.