LS150-001 Cabin Speaker
Installation and Operation Manual
July 19, 2017 Rev: 1.00
Page 2-1
ENG-FORM: 805-0102.DOTX
CONFIDENTIAL AND PROPRIETARY TO ANODYNE ELECTRONICS MANUFACTURING CORP.
Section 2.0 Installation
2.1
Introduction
Information in this section consists of: unpacking and inspection procedures, installation procedures, post-
installation checks, and installation drawings.
2.2
Unpacking and Inspection
Unpack the equipment carefully. Inspect the unit visually for damage due to shipping and report all such
claims immediately to the carrier involved. Note that each unit should have the following:
- LS150-001
- Acceptance Test Report
- Certificate of Conformity or Release certification
Verify that all items are present before proceeding and report any shortage immediately to your supplier.
2.2.1
Warranty
All Anodyne Electronics Manufacturing Corp. (AEM) products are warranted for 2 years. See the website
www.aem-corp.com/warranty for complete details.
2.3
Installation Procedures
2.3.1
Warnings
WARNING:
When the speaker is connected to an appropriate amplifier, the system
is capable of producing high sound pressure levels. Proper personal
protective equipment is required to prevent hearing damage.
2.3.2
Cabling and Wiring
All wire shall be selected in accordance with the original aircraft manufacturer's Maintenance Instructions
or AC43.13-1B Change 1, Paragraphs 11-76 through 11-78. Unshielded wire types shall qualify to MIL-W-
22759 as specified in AC43.13-1B Change 1, Paragraphs 11-85, 11-86, and listed in Table 11-11. For
shielded wire applications, use Tefzel MIL-C-27500 shielded wire with solder sleeves (for shield
terminations) to make the most compact and easily terminated interconnect. Follow the interconnect
drawing in Section 2.7 as required.
Maintain wire segregation and route wiring in accordance with the original aircraft manufacturers
Maintenance Instructions.
Unless otherwise noted, all wiring shall be a minimum of 14 AWG. Reference the Interconnect drawing for
additional specifications. Check that the ground connection is clean and well secured.