DK-9523 is an universal, self-contained digital access keypad offers field proven reliability and cost effective

solutions for residential and commercial installations. It is designed for stand alone electric lock and inter-lock

systems and operates from a 12 to 24V AC/DC power supply. It is virtually compatible with any electric locking

device. Apart from that it is also the perfect choice for controlling security systems, automatic operators and

machinery.
DK-9523 consists two application softwares of Single User Mode for the general Users, and Multi-User Mode for

the advanced Users. The system offers a 4 digit length user code with 10,000 combinations for each output in

single user mode; and 100 user codes for output 1 and 10 user codes each for output 2 and output 3 in length of

4-8 digits with combinations of more than 100 million in multi-user mode. Operation options of Auto Code entry

and Manual Code entry are available in both two user modes. Programmed information that stored in the system

are non-volatile in power failure.
The DK-9523 offers three outputs with the following facilities:

The connection facilities consist one set of terminal block mainly for Output 1 for door striking purpose; and one

set of wire harness for Output 2 and 3, and the facilities for those auxiliary functions.

5 Amp relay dry contacts, recommended for door strike controls. Normally Open (N.O.) and Normally Closed

(N.C.) outputs are available. Use N.O. output for Fail-secure locking device and N.C. output for Fail-safe locking

device. The relay can be programmed in Start/Stop (toggle) mode or timer mode from 1 to 999 seconds.

THE TERMINAL BLOCK

!

OUTPUT 1

CONNECTION FACILITIES

2

OUTPUT 1

5 Amp relay

OUTPUT 3

NPN Open Collector

OUTPUT 2

1 Amp relay

WHITE/ORANGE

DURESS OUTPUT

YELLOW GREEN

( ) GND

-

BROWN

INTERLOCK CONTROL

ORANGE

OUTPUT 1 INHIBIT

WHITE/RED

OUTPUT 3

OUTPUT 2

RELAY

PURPLE

(N.C.)

YELLOW

(+)

LIGHT BLUE

( )

-

GREEN

(+)

GREY

( )

-

BLACK

RED

RED LED

GREEN LED

TAMPER

AUXILIARY RED LED ( )

-

WHITE

KEYPAD ACTIVE OR ALARM OUTPUT

PINK

BLUE

(N.O.)

WHITE/BROWN

(COM)

1

16

2

15

3

14

4

13

5

12

6

11

7

10

8

9

DK-9523

ON OFF

DAP

KEY AL

KO
RA

(+

)(

)

-

12-24V

AC/DC

EG IN

OUTPUT

1

N.C.

C.

N.O.

DOOR SENS

TAMP

RELAY

1

RELAY

2

1 2 3 4 5 6 7 8 9 1011 121314 1516

19

The Duress Output will switch to ( ) ground when duress code is entered. You may use it to turn ON an LED

lamp and /or a small buzzer to notify a guard; or connect it to a 24 hour Normally Open protection zone of an

alarm system.

-

F

Only one connection option is recommended. Make sure that the sink current does not exceed the maximum

rating of 100mA.

(D) DURESS OUTPUT

(WHITE/ORANGE WIRE)

(E) OUTPUT 2

OR

1.5K

LED

+12V

LOW POWER

PIEZO BUZZER

(10)

(11)

(12)

(13)

(14)

(15)

(16) WHITE/ORANGE

WIRE HARNESS

ALARM CONTROL PANEL

24 HOUR N.O.

PROTECTION

ZONE

(10)

(11)

(12)

(13)

(14)

(15) YELLOW GREEN

(16) WHITE/ORANGE

WIRE HARNESS

( i ) Shunting an N.C. Zone

(WHITE/BROWN & BLUE WIRES)

F

F

Use the Normally Open (N.O.) output contact to shunt a Normally Closed (N.C.) protection zone of an

alarm system.
Set output contact to Start / Stop Mode (Programming Option 51).

( ii ) Alarm System Arm-Disarm Control

(WHITE/BROWN & BLUE or PURPLE WIRES)

F
F
F

Use the (N.O.) or (N.C.) output contact to make arm-disarm control of an alarm system.
Consult your alarm control panel manual for the appropriate output contact to be used in arm-disarm control.
Usually set output 2 to Momentary mode (Programming Option 501) for multi station systems and Start

/ Stop mode (Programming Option 51) for single station systems.

WIRE HARNESS

(8)
(9) WHITE/BROWN
(10) BLUE
(11) PURPLE
(12)

OR

ALARM CONTROL PANEL

REMOTE

ARM-DISARM

CONTROL

NO. OR N.C.

WIRE HARNESS

(8)
(9) WHITE/BROWN
(10) BLUE
(11)
(12)

N.C.

N.C. MAGNETIC CONTACT

TO PROTECTION ZONE

OF AN ALARM CONTROL PANEL

Summary of Contents for DK-9523

Page 1: ...of an alarm system The Duress Inter lock Key Active Outputs of the keypad are open collector output OPEN COLLECTOR OUTPUT Output switches to ground when activates N O CONTACT OUTPUT Output switches t...

Page 2: ...OUTPUT 2 1 Amp relay WHITE ORANGE DURESS OUTPUT YELLOW GREEN GND BROWN INTERLOCK CONTROL ORANGE OUTPUT 1 INHIBIT WHITE RED OUTPUT 3 OUTPUT 2 RELAY PURPLE N C YELLOW LIGHT BLUE GREEN GREY BLACK RED RED...

Page 3: ...if it is not used Connect to 12 24V AC or DC power supply The supply and GND wire 15 are the common grounding points of the keypad system No selection jumper is required for the full input voltage ran...

Page 4: ...lamp changes to steady Red while the auxiliary Red LED is energized The built in buzzer and the green LED indicator at the centre give the following tones and signals for operation status All Pacifier...

Page 5: ...quired to apply the following procedures precisely Disconnect power supply Displace the DAP jumper from OFF to ON position Reconnect power supply buzzer is activated Put the DAP jumper back to OFF pos...

Page 6: ...g Installer Programming NOTE Locations Code of Duration Locations No of False Entry Validation Comments Validation Comments Locations Code of Functions Validation Comments Locations Code of Functions...

Page 7: ...is always set with Auto Code Entry in default The user does not require to press the key in user code entry The user only needs to enter the 4 digit user code The relay will activate for the programm...

Page 8: ...ressed Multi User Mode on Duty please wait 2 3 seconds until the confirmation beeps are heard after the key is pressed SET THE SYSTEM TO SINGLE USER MODE SET THE SYSTEM TO MULTI USER MODE REFRESH THE...

Page 9: ...for output 2 3 and the key to delete a user code You may delete other user code s in this fashion Exit the programming mode by pressing the key after the work is done 1 2 3 4 3289 1 05 The keypad is...

Page 10: ...Code of The Accelerated Code will be Duress output activates output switches to ground Output 1 activates for 1 second Output 1 starts Output 1 stops 0321 83 8321 8321 83 C MULTI USER MODE OPERATION...

Reviews: