ARGONAUT™ IC2
|
USER MANUAL
|
15
Argonaut IC2 with LPCCE Earplugs
tested to
ANSI S3.19-1974
Frequency (Hz)
125
250
500 1000 2000 3150 4000 6300 8000
Mean (dB)
33.9
37.7
44.8
43.0
41.5
49.6
52.2
49.6
48.8
Stand. Dev. (dB)
4.6
2.9
4.0
3.7
3.3
3.9
4.1
3.3
4.3
Mean-2SD (dB)
24.7
31.9
36.8
35.6
34.9
41.8
44.0
43.0
40.2
Argonaut IC2 with FCCCE Earplugs
tested to
ANSI S3.19-1974
Frequency (Hz)
125
250
500 1000 2000 3150 4000 6300 8000
Mean (dB)
33.4
38.3
45.3
42.4
45.5
50.9
50.7
51.2
50.9
Stand. Dev. (dB)
4.7
4.5
3.6
3.8
3.1
5.2
5.6
6.0
6.0
Mean-2SD (dB)
24.0
29.3
38.1
34.8
39.3
40.5
39.5
39.2
38.9
Noise
Reduction
Rating
35
(WHEN USED AS DIRECTED)
DECIBELS
THE RANGE OF NOISE REDUCTION RATINGS FOR EXISTING
HEARING PROTECTORS IS APPROXIMATELY 0 TO 30
(HIGHER NUMBERS DENOTE GREATER EFFECTIVENESS).
Aegisound
Christiansburg, Virginia
Argonaut IC2 with
LPCCE Earplugs
Federal law prohibits
removal of this label
prior to purchase
Label Required by U.S. EPA
regulation 40 CFR part 211,
subpart B
Noise
Reduction
Rating
35
(WHEN USED AS DIRECTED)
DECIBELS
THE RANGE OF NOISE REDUCTION RATINGS FOR EXISTING
HEARING PROTECTORS IS APPROXIMATELY 0 TO 30
(HIGHER NUMBERS DENOTE GREATER EFFECTIVENESS).
Aegisound
Christiansburg, Virginia
Argonaut IC2 with
FCCCE Earplugs
Federal law prohibits
removal of this label
prior to purchase
Label Required by U.S. EPA
regulation 40 CFR part 211,
subpart B