QuickSwitch™ – Instruction Manual
4.3.
Use with General Test Equipment.
For connection to the Equipment side of the MDF or Mains side of a CCU
1.
Select the
QuickSwitch™ Plug
to suit the IDS Module you wish to connect to.
2.
Ensure the switch is in the Monitor (Bridging) Position.
3.
Plug in the
QuickSwitch™
and note the direction of the Exchange.
4.
Plug test/monitor instrument into the switching sockets at the base of the switch housing.
5.
Unless intentionally being used, ensure the non switching sockets are clear from any other
connection.
6.
Check the line to ensure it is not in use. (Eg; Buttinski)
7.
If a test is to be conducted using an
Exchange
feature or facility, and the
customer
side
(Country) is to be
included
in the test, then leave the switch in the
Monitor
position.
8.
If a test is to be conducted using an
Exchange
feature or facility, and the
customer
side
(Country) is to be
excluded
in the test, then rotate the switch to the
Exchange
position.
9.
If a test is to be conducted using a
Country
feature or facility, and the
exchange
side is to be
excluded
in the test, then rotate the switch to the
Customer
position.
10.
Ensure all connections are removed from the
QuickSwitch™
before it is removed from the
IDS Module.
4.4.
Use with RJ Adaptor.
1.
When using the RJ Adaptor, make sure that the
QuickSwitch™
must be set to Monitor
position.