Summary of Contents for X-SLIM 35 EC

Page 1: ...OPERATION AND INSTALLATION INSTRUCTIONS SHOWER WATER HEATER MODEL X SLIM 35 EC X SLIM 45 EC ...

Page 2: ...2 ...

Page 3: ...rence If the appliance is passed on to a third party please hand these instructions to the new user This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Children shoul...

Page 4: ...Fig 2 Dimension Wall Mounting Fig 3 Fig 4 Cable Wiring diagram 220 240 VAC ONLY Flow SW A B C D E A Heating Element B X Slim PC Front PCB C ELCB D X Slim PC Control PCB E Thermal Cut Out 3 Installation Instruction for the qualified installer ...

Page 5: ...eatingofthewateriselectronically controlled and the flow is switched on and off by using the water valve Once the flow volume is sufficient the Power light will indicate that the unit is switched on For safety the unit is fitted with an overheating protection device 1 2 The essentials in brief a Water valve b Rotary control for temperature adjustment c Power light d Shower accessories Installation...

Page 6: ...ch on the electrical supply then press the Reset Button E How to test When the ELCB test button F is pressed the ELCB Reset E Button will drop When the reset button E is pressed the unit will be ready to operate again Warning If the unit does not operate even when pressing the Reset button contact service center for a check and repair 1 3 2 The unit is equipped with a Double action thermostat In c...

Page 7: ...on thermostat 6 Cable entry with seal 7 Terminal block for earth wire 8 ELCB 9 Connector to PCB control Base 10 Reed switch 11 ELCB reset button 12 ELCB test button 13 Cold water connection 14 Hot water connection for shower hose 15 X SLIM tank base 16 Tank cap 17 Filter 18 Rubber seal 19 Water Valve 20 Power Light 21 Connector to PCB Control Cover Installation Instruction for the user and the qua...

Page 8: ...oles by installation template and drill the holes Release cover securing screw Open and remove cover Insert the wall plugs and screw make sure insertion depth is correct Fig 2 number 3 Ensure that the ELCB is switched off Feed the connection cable seal in the rear wall Installation Instruction for the user and the qualified installer ...

Page 9: ...er size in technical data table Guide the unit over the wall securing screws and slide it downwards Fit a secure connection cable ensure dimensions are correct The unit must be earthed properly see circuit diagram Fig 4 See recommended cable size in technical data table Installation Instruction for the user and the qualified installer ...

Page 10: ... 19 Fig 17 Straighten the unit and tighten the screws Connect the electrical supply from cover into the PCB control Fit the cover and secure with the screw Installation Instruction for the user and the qualified installer ...

Page 11: ...ntherotarycontroltothe off position Fit the filter and silicone gasket Fig7number 17 18 Fitthecoldwaterpipethoroughly Fig7number 20 Fit the shower accessories to the unit Installation Instruction for the user and the qualified installer ...

Page 12: ...n a frost free location since there will always be some water left in the unit The shower unit is to be installed vertically on a wall water connection downwards The outlet must not be connected to any tap or fitting other than those specified Type 35 EC 45 EC Norminal capacity l 0 35 Design Open Min water pressure to activate unit 0 15 bar 0 015 MPa Water connection G External Thread Dimension W ...

Page 13: ...ur To avoid risk of scalding stay away from the shower head discharge zone momentarilly The hot water temperature dependsonthepowerofthe unit the cold water temperature and the flow volume 4 Care and Maintenance When carrying out any work switch off the circuit braker to isolate the electrical power and cutt off the water connection All that is needed for cleaning of the housing is a damp cloth Do...

Page 14: ...by themselves always get a certified installer Hand over this instruction manual to the user and to be kept in safe place for future reference 7 Guarantee For guarantees please refer to the respective terms and conditions of supply for your country The installation electrical connectionandfirstoperation of this appliance should be carried out by a qualified installer The company does not accept li...

Page 15: ...ification No hot water despite water flow through the unit The water flow volume required for the unit to turn it on has not been reached Increase flow volume The shower head is blocked with dirt or limescale Clean shower head or remove limescale ELCB activated Press ELCB Reset button ...