t
Press and hold the menu
and down buttons at the same time.
RX
icon will be displayed on the LCD screen. Your PMR will pick up
signals on the current channel, including background noise.
t
Press the menu button
to stop the channel monitoring.
4.7
Setting the VOX (voice activated) sensitivity
In VOX mode, the unit will transmit a signal only when it is activated by
your voice or other sounds around you. The unit will transmit further
for 2 seconds even if you stop talking.
The level of VOX sensitivity is shown by a number on the LCD screen.
At the highest level, the units will pickup softer noise (including
background noise); at the lowest level, it will pick up only louder noise.
t
Press the menu button
4 times,
VOX
icon will be displayed and
“OF” flashes on the LCD screen.
t
Press the up button to set the VOX sensitivity into maximum level
(the maximum level is 3.)
t
To deactivate the VOX function, press the down button until “OF”
appears on the LCD screen.
t
Press the PTT button to confirm your setting.
VOX
will steady
appear on the LCD screen as along as the VOX feature is activated.
Note:
VOX operation is not recommended if the unit will be used in a noisy
or windy environment.
4.8
Activating the auto channel scan
Channel scan perform searches for active signals in an endless loop for
all 8 channels, 38 CTCSS codes and all 83 DCS codes.
t
Press the menu button
5
times,
SCAN
icon will display on LCD
screen.
t
Press the up or down button to begin scanning channels when
an active signal is detected, channel scan pauses on the active
channel.
t
Press the menu button
six times,
CTCSS
flashes on the LCD
screen press the up or down button to begin scanning the
CTCSS from 1-38.