Problem
Possible cause
Remedy
The drying cycle is
too short.
The load size is small.
Select a time program. The time value must
be related to the load. To dry one item or a
small amount of laundry we recommend
short drying times.
The laundry is too dry.
Select an appropriate time program or a
higher dryness level (e.g.
extra dry
)
Drying cycle too
long
5)
The filter is clogged.
Clean the filter.
The load is too large.
Do not exceed the maximum load size.
The laundry was not spun sufficiently.
Spin the laundry well in the washing ma‐
chine.
Too low or too high room temperature - this
is not the appliance malfunction.
Ensure a room temperature higher than
+5°C and lower than +35°C. Optimal room
temperature to achieve best drying results
is between 18°-25°C.
1)
Follow the program description — see the PROGRAMS chapter .
2)
See the
CARE AND CLEANING
chapter.
3)
Only dryers with the Dryness Level option.
4)
See the HINTS AND TIPS chapter .
5)
Note: After a maximum of 5 hours the drying cycle ends automatically.
11.3 Possible causes of
unsatisfactory drying results:
• The filter is clogged. Clogged filter makes
drying inefficient.
• The airflow slots are clogged.
• The humidity sensor is dirty.
• The drum is dirty.
• Inadequate default dryness level settings.
See chapter
Adjustment of default dryness
level
• Room temperature is too low or too high.
Optimal room temperature is between
18°-25°C.
12. TECHNICAL DATA
Height x Width x Depth
850 x 596 x 638 mm (maximal 663 mm)
Max. depth with the appliance door open
1108 mm
Max. width with the appliance door open
958 mm
Adjustable height
850 mm (+ 15 mm - feet regulation)
Drum volume
118 l
Maximum load volume
9,0 kg
Voltage
230-240 V
Frequency
50 Hz
Sound power level
64 dB
Necessary fuse
13 A
ENGLISH 25