23
Symptom
Possible Cause
Remedy
Appliance does not work.
Appliance is not switched
on.
Mains plug is not plugged
in or is loose.
Fuse has blown or is
defective
Socket is defective.
Mains malfunctions are to
be corrected by an
electrician.
Temperature is set too
cold.
Turn the temperature reg-
ulator to a warmer
setting temporarily.
Switch on the appliance.
Insert mains plug.
Check fuse, replace if nec-
essary.
Appliance cools too much.
The food is too warm.
Temperature is not
properly adjusted.
Please look in the “Initial
Start Up” section.
Light bulb is defective.
Interior lighting does not
work.
Door was open for an
extended period.
A large quantity of warm
food was placed in the
appliance within the last
24 hours.
The appliance is near a
heat source.
Open the door only as long
as necessary.
Turn the temperature reg-
ulation to a colder setting
temporarily.
Please look in the
“Installation location” section.
Please look in the “Changing
the Light Bulb” section.
Heavy build up of frost,
possibly also on the door
seal.
Door seal is not air tight
(possibly after reversing
the door).
Carefully warm the leaking
sections of the door seal
with a hair dryer (on a
cool setting). At the same
time shape the warmed
door seal by hand such
that it sits correctly.
Unusual noises.
Appliance is not level.
The appliance is touching
the wall or other objects.
Readjust the feet.
Move the appliance
slightly.
The compressor does not
start immediately after
changing the temperature
setting.
This is normal, no error has
occurred.
The compressor starts after
a period of time.
Summary of Contents for SANTO 1583-7 TK