8.3 Defrosting of the
appliance
Frost is automatically eliminated from the
evaporator of the refrigerator
compartment every time the motor
compressor stops, during normal use.
The defrost water drains out through a
trough into a special container at the
back of the appliance, next to the motor
compressor, where it evaporates.
8.4 Periods of non-operation
When the appliance is not in use for long
periods, take the following precautions:
1. Disconnect the appliance from
electricity supply.
2. Remove all food.
3. Clean the appliance and all
accessories.
4. Leave the doors open to prevent
unpleasant smells.
9. TROUBLESHOOTING
WARNING!
Refer to Safety chapters.
9.1 What to do if...
Problem
Possible cause
Solution
The appliance does not op‐
erate.
The appliance is switched
off.
Switch on the appliance.
The mains plug is not con‐
nected to the mains socket
correctly.
Connect the mains plug to
the mains socket correctly.
There is no voltage in the
mains socket.
Connect a different electrical
appliance to the mains sock‐
et. Contact a qualified elec‐
trician.
The appliance is noisy.
The appliance is not suppor‐
ted properly.
Check if the appliance
stands stable.
The compressor operates
continually.
Temperature is set incorrect‐
ly.
Refer to the "Operation"
chapter.
Many food products were
put in at the same time.
Wait a few hours and then
check the temperature
again.
The room temperature is too
high.
Refer to the "Installation"
chapter.
Food products placed in the
appliance were too warm.
Allow food products to cool
to room temperature before
storing.
The door is not closed cor‐
rectly.
Refer to the "Closing the
door" section.
The Super Freezing function
is switched on.
Refer to the "Super Freezing
function" section.
www.aeg.com