background image

1

English

INTRODUCTION

This product has many features for making its use more pleasant 

and enjoyable. Safety, performance, and dependability have 

been given top priority in the design of this product, making it 

easy to maintain and operate.

 DANGER

 

GROUNDING THE GENERATOR 

(See Figure 1)

 

To avoid the risk of shock or electrocution, the generator 

must be properly grounded. The nut and ground terminal 

on  the  frame  must  always  be  used  to  connect  the 

generator to a suitable ground source. The ground path 

should  be  made  with  0.75m

2

  size  wire.  Connect  the 

terminal of the ground wire between the lock washer 

and the nut, and tighten the nut fully. Connect the other 

end of the wire securely to a suitable ground source.

ImpORTANT sAfETy INsTRUCTIONs

 

WARNING:

 

Read  and  understand  all  instructions.

  Failure 

to  follow  all  instructions  listed  below  may  result 

in  electrocution,  fire,  and/or  carbon  monoxide 

poisoning, which will cause death or serious injury.

 

  WARNING:

 

National Electric Code requires the generator to be 

grounded to an approved earth ground. Before using 

the  ground  terminal,  consult  a  qualified  electrician, 

electrical  inspector,  or  local  agency  having 

jurisdiction for local codes or ordinances that apply 

to the intended use of the  generator.

sAVE THEsE INsTRUCTIONs

This  manual  contains  important  instructions  that  should  be 

followed during installation and maintenance of the generator 

and batteries.

n

 

Do not allow children or untrained individuals to use this 

unit.

n

 

Never start or run the engine inside a closed or partially 

enclosed area. Breathing exhaust fumes will kill you.

n

 

Wear eye protection as well as hearing protection when 

operating this equipment.

n

 

Keep all bystanders, children, and pets at least 3m away.  

n

 

Wear sturdy and dry shoes or boots. Do not operate while 

barefoot.

n

 

Do not operate the generator when you are tired or under 

the influence of drugs, alcohol, or medication.

n

 

Keep all parts of your body away from any moving parts 

and all hot surfaces of the unit.

n

 

Product  users  in  some  states,  must  comply  with  fire 

prevention regulations. This product is not equipped with 

a spark arrestor. Check with the federal, areas, or local 

authorities in your area before use.

n

 

Do not touch bare wire or receptacles.

n

 

Do not use the generator with electrical cords which are 

worn, frayed, bare, or otherwise damaged.

n

 

Before storing, allow the engine to cool.

n

 

Do not operate the generator in rain, snow, or wet weather.

n

 

Empty fuel tank, close fuel valve, and restrain the unit from 

moving before transporting in a vehicle.

n

 

Allow engine to cool for five minutes before refueling.

n

 

To reduce the risk of fire and burn injury, handle fuel with 

care. It is highly flammable.

n

 

Do not smoke while handling fuel.

n

 

Store fuel in a container approved for unleaded fuel.

n

 

Position the unit on level ground, stop engine, and allow 

to cool before refueling.

n

 

Loosen fuel cap slowly to release pressure and to keep 

fuel from escaping around the cap.

n

 

Tighten the fuel cap securely after refueling.

n

 

Wipe spilled fuel from the unit.

n

 

Never  attempt  to  burn  off  spilled  fuel  under  any 

circumstances.

n

 

Use only authorised replacement parts and accessories and 

follow instructions in the Maintenance section of this manual. 

Use of unauthorised parts or failure to follow Maintenance 

instructions may create a risk of shock or injury.

n

 

Maintain  the  unit  per  maintenance  instructions  in  this 

Operator’s Manual.

n

 

Inspect the unit before each use for loose fasteners, fuel 

leaks, etc. Replace damaged parts.

n

 

The generators vibrate in normal use. During and after 

the use of the generator, inspect the generator as well as 

extension cords and power supply cords connected to it 

for damage resulting from vibration. Have damaged items 

repaired or replaced as necessary. Do not use plugs or 

cords that show signs of damage such as broken or cracked 

insulation or damaged blades.

Summary of Contents for Powertools AGN3800B

Page 1: ...Original Instructions AGN3800B PORTABLE GENERATOR SET ...

Page 2: ...stick recoil starter grip air filter choke lever fuel valve FUEL CAP FUEL tank Fuel level gauge Fuel level gauge Circuit Breaker fuel tank fuel cap oil cap dipstick oil fill hole carburetor drain screw oil cap dipstick Fig 2 Fuel level gauge oil fill hole ...

Page 3: ...Fig 6 ON OFF ON OFF Fig 8 Fig 7 recoil startER grip fuel valve CHOKE LEVER TO START choke closed TO run choke open LATCHES air filter cover filter elementS air filter unit Fig 9 ...

Page 4: ...21 2 Fig 10 ON OFF Fig 11 Fig 12 Fig 13 ON OFF ON OFF spark plug cap spark plug fuel line fuel valve BARB fuel valve o ring filter sediment cup oil cap dipstick ...

Page 5: ...hen you are tired or under the influence of drugs alcohol or medication n Keep all parts of your body away from any moving parts and all hot surfaces of the unit n Product users in some states must comply with fire prevention regulations This product is not equipped with a spark arrestor Check with the federal areas or local authorities in your area before use n Do not touch bare wire or receptacl...

Page 6: ...l types of combustible material n Do not operate the generator near hazardous material n Do not operate the generator at a gas or natural gas filling station n Do not touch the muffler or cylinder during or immediately after use they are HOT and will cause burn injury n Do not connect to a building s electrical system unless a transfer switch has been properly installed by a qualified electrician ...

Page 7: ... face shield when operating this product Safety Alert Precautions that involve your safety Electric Shock Failure to use in dry conditions and to observe safe practices can result in electric shock Toxic Fumes Running the generator gives off carbon monoxide an odorless colorless poison gas Breathing carbon monoxide can cause nausea fainting or death Fire Explosion Fuel and its vapors are extremely...

Page 8: ...jects being thrown into your eyes which can result in severe eye damage Before beginning power tool operation always wear safety goggles or safety glasses with side shields and when needed a full face shield We recommend Wide Vision Safety Mask for use over eyeglasses or standard safety glasses with side shields Always wear eye protection SAVE THESE INSTRUCTIONS The following signal words and mean...

Page 9: ...The unit is equipped with an oil sensor which will automatically shut off the engine if oil level falls below a safe limit Hot SURFACE warning Do not touch the muffler or aluminum cylinder of the engine They are very HOT and will cause severe burns Don t put any flammable or combustible materials in the direct path of the exhaust ICON WARNING READ THE OWNERS MANUAL AND ALL LABELS BEFORE OPERATING ...

Page 10: ...t the engine as described later in this manual 2 Plug in and turn on the first load preferably the largest load you have 3 Permit the generator output to stabilise engine runs smoothly and attached device operates properly 4 Plug in and turn on the next load 5 Again permit the generator to stabilise 6 Repeat steps 4 and 5 for each additional load Never add more loads than the generator capacity Ta...

Page 11: ... Type 4 Stroke air cooled OHV Gasoline Bore x Stroke 77x58 Displacement cc 270 Starting System recoil Fuel Type Unleaded fuel Lubrication oil SAE 10W 30 Engine Oil Volume L 1 0L Fuel Tank Capacity l 25 Max Output hp 9 0 Max Output rpm 3 600 Full Load h 10 Half Load h 18 Approvals CE Yes Euro Emission Yes 4m Noise Level LpA dB A 76 4m Noise Level LwA dB A 96 Uncertainty dB A 2 7m Noise Level LpA dB...

Page 12: ...ceptacleS Your generator has the following single phase 50 Hz outlets one 230 Volt AC 16 Amp receptacle These can be used for operating appropriate appliances electrical lighting tools and motor loads recoil starter grip The recoil starter grip is used along with the engine switch to start the generator s engine DC TERMINALS The DC terminals may ONLY be used for charging 12 volt automotive type ba...

Page 13: ...ith tools to make you careless Remember that a careless fraction of a second is sufficient to inflict serious injury WARNING Do not use any attachments or accessories not recommended by the manufacturer of this product The use of attachments or accessories not recommended can result in serious personal injury APPLICATIONS This generator is designed to supply electrical power for operating compatib...

Page 14: ...alled in a vehicle disconnect the vehicle ground battery cable from the battery negative terminal n Connect the positive battery cable to the battery positive terminal n Connect the other end of the positive battery cable to the generator positive terminal n Connect the negative battery cable to the battery negative terminal n Connect the other end of the negative battery cable to the generator ne...

Page 15: ...elements in the air filter unit n Replace the air filter cover and close latches to secure NOTE Do not run the generator without the air filter Rapid engine wear will result changing engine oil See Figure 10 n Remove the oil cap dipstick n Place a container underneath the oil drainage bolt to collect used oil as it drains n Unscrew the oil drainage bolt and remove n Allow oil to drain completely n...

Page 16: ...ngine switch off O n Close fuel valve n Remove the fuel line from the barb by squeezing the ends of the retaining clip and sliding the fuel line off n Install one end of a drain line over the barb and place the other end in a fuel container large enough to catch the fuel being drained from the tank n Open fuel valve n When the fuel has drained from the tank close the fuel valve and reinstall fuel ...

Page 17: ...ife Forrecommendations contactyournearestauthorizedservicecenter MAINTENANCE SCHEDULE Before each use After 1st month or 20 hours of operation Every 3 months or 50 hours of operation Every 6 months or 100 hours of operation Every year or after 300 hours of operation Check Engine Oil n Change Engine Oil n n Check Air Filter n Clean Air Filter n Change Air Filter n Clean Carburetor Sediment Cup n Ch...

Page 18: ...Circuit breaker is off Item plugged in is defective Turn ON the AC circuit breaker Try a different item Generator makes a spark knock or pinging noise An occasional light knocking or pinging underheavyloadisnotacause for concern However if the knocking or pinging occurs under normal load at a steady engine speed the problem may be with the brand of unleaded fuel being used Switch to a different br...

Page 19: ...15 English WIRING DIAGRAM AGN3800B ...

Page 20: ...zed reseller or if product is sold AS IS and or WITH ALL FAULTS Where permitted the provisions of this limited warranty are in lieu of any other written warranty whether express or implied written or oral including any warranty of MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE IN NO EVENT SHALL WE BE LIABLE FOR SPECIAL INCIDENTAL CONSEQUENTIAL OR INCIDENTAL DAMAGES OUR MAXIMUM LIABILITY SHALL...

Page 21: ...4 0 91 627 93 29 TECHTRONIC INDUSTRIES ASIA CO LTD 24 F CDW Building 388 Castle Peak Road Tsuen Wan Hong Kong Tel 852 2402 6888 RYOBI TECHNOLOGIES GMBH Itterpark 4 D 40724 Hilden DEUTSCHLAND Tel 49 0 2103 2958 0 Fax 49 0 2103 2958 29 RYOBI TECHNOLOGIES GMBH Vertriebsbüro Österreich Schinitzgasse 13 A 8605 Kapfenberg Tel 43 0 3862 23590 0 Fax 43 0 3862 23590 25 TECHTRONIC INDUSTRIES AUSTRALIA PTY L...