Your appliance needs air
For safety reasons, minimum
ventilationmust be as shown
Fig.
Attention: keep ventilation
openings clear of obstruc-
tion;
50 mm
min.
cm
2
200
200 cm
2
min.
D567
Rehingeing the door
The side at which the door opens can be changed from the right side
(factory adjustment) to the left side, if the installation site requires.
Warning!
When changing the side at which the door opens, the
appliance may not be connected to the mains. Remove plug from the
mains beforehand.
If installation next to a source of heat is unavoidable, the following
minimum clearances must be maintained at the sides of the applian-
ce:
Ð for electric cookers 3 cm;
Ð for oil and coal fired ranges 30 cm.
If these clearances cannot be maintained a heat insulating pad is
required between the cooker and the refrigeration appliance.
If the refrigeration appliance is installed next to another refrigerator or
freezer a clearance of 5 cm at the sides is required, in order to pre-
vent the formation of condensation on the outside of the appliance.