41
www.aeg.com
can be moved if servicing is ever
required.
6. A U.L. listed conduit connector
must be provided at each end of
the power supply cable.
19.4.
Electrical connections
Be sure your appliance is properly
installed and grounded by a qualified
technician. Ask your dealer to
recommend a qualified technician or
an authorized repair service.
This appliance is manufactured with a
green GROUND wire connected to the
oven chassis. After making sure that
the power has been turned off,
connect the flexible conduit from the
oven to the junction box using a U.L.
listed conduit connector. The figures
and the instructions provided below
present the most common way of
connecting the ovens.
Your local codes and ordinances, of
course, take precedence over these
instructions.
WARNING” Risk of Electric Shock,
frame grounded to neutral of appliance
through a link.
Grounding
through
the
neutral
conductor is prohibited for new branch-
circuit installations (1996 NEC); mobile
homes; and recreational vehicles, or in
an area where local codes prohibit
grounding
through
the
neutral
conductor. For installations where
grounding
through
the
neutral
conductor is prohibited:
Disconnect the ground from the
neutral at free end of conduit;
Use grounding terminal or lead to
ground unit; and
Connect neutral terminal or lead to
branch circuit neutral in usual
manner.
19.5.
3-Wire branch circuit (for
US only)
Refer to the following Figure, where
local codes allow the connection of
GROUND wire from the oven to the
branch circuit NEUTRAL wire (gray or
white colored wire):
If local codes permit, connect
the green GROUND wire from
the oven and the white wire
from the oven to the branch
circuit NEUTRAL wire (gray or
white colored wire).
Connect the red and black leads from
the oven to the corresponding leads in
the junction box.
19.6.
4-Wire branch circuit (for
US and CANADA)
Refer to the following Figure:
Disconnect ground from neutral at
free end of conduit.
Connect the green GROUND wire
from the oven to the GROUND wire
in the junction box (bare or green
colored wire).
Connect the red and black leads from
the oven to the corresponding leads in
the junction box.