3.
Put the two ends of the inlet hose in
a container and let the water flow out
of the hose.
4.
Empty the drain pump. Refer to the
emergency drain procedure.
5.
When the drain pump is empty,
install the inlet hose again.
WARNING!
Make sure that the
temperature is higher than 0
°C before you use the
appliance again.
The manufacturer is not
responsible for damages
caused by low temperatures.
13.
TROUBLESHOOTING
WARNING!
Refer to Safety chapters.
13.1
Introduction
The appliance does not start or it stops
during operation.
First try to find a solution to the problem
(refer to the table). If the problem
persists, contact the Authorised Service
Centre.
With some problems, the acoustic
signals operate and the display shows
an alarm code:
•
- The appliance does not fill with
water properly. Start the appliance
again by pressing Départ/Pause
button. After 10 seconds the door will
be unlocked.
•
- The appliance does not drain
the water.
•
- The appliance lid or drum
doors are open or not closed
correctly. Please check both!
•
- The mains supply is unstable.
Wait until the mains supply is stable.
•
- The anti-flood device is on.
Disconnect the appliance and close
the water tap. Contact the Authorised
Service Centre.
WARNING!
Deactivate the appliance
before you do the checks.
13.2
Possible failures
Problem
Possible solution
The programme does
not start.
• Make sure that the mains plug is connected to the mains
socket.
• Make sure that the appliance lid and drum doors are closed
properly.
• Make sure that there is no damaged fuse in the fuse box.
• Make sure that the Départ/Pause has been touched.
• If the delay start is set, cancel the setting or wait for the end
of countdown.
• Deactivate the Child Lock function if it is on.
ENGLISH
27