www.aeg-automotive.com
26
Completing charging and disconnecting the
charger
1.
Press the „START / STOP“ button (3) to finish
the charging process.
2. First, remove the plug from the 230V power
socket.
3.
Disconnect the black (-) terminal connection
cable with clamp (6) from the negative battery
terminal.
4.
Disconnect the red (+) terminal connection cable
with clamp (5) from the positive battery terminal.
ChARGING PhASES
The concept of the charging process is explained
based on a 12 V battery.
Diagnosis
Diagnostic function which automatically checks the
battery status and recognises the voltage.
Voltage
Function
0 V bis 1.5 V
“Error” LED (15) lit. Battery defective.
1.5 V bis 12 V
Charging starts.
12 V bis 13 V
Maintenance charging starts.
14.6 V
Battery fully charged. “Full” LED
(13) lit.
>15 V
“Error” LED (15) lit.
Step 1: Condition check
The charger checks the battery condition and calcu
-
lates the required
charging parameters.
8
2
V
A
3
4
5
6
7
9
1
Step 2: Desulphation (rescue)
•
The charger can rescue most drained batteries
with voltages up to a minimum of 1.5
±
0.5 V.
•
The safety switch does not allow the charger to
start charging if the voltage is below 1.5
±
0.5 V.
•
At a voltage range of 1.5
±
0.5 V to 10.5
±
0.5 V
the charger will initiate pulse charging.
•
If the voltage rises above 10.5
±
0.5 V, the charger
will switch to the previously selected regular
charging mode, which will charge faster and more
safely.
Step 3: Precharging
The battery is gently charged with a low charging
current to return the battery to a chargeable state.
Step 4: Soft start
The battery is gently charged with a low charging
current.
Step 5: Base charge with a constant current
The battery is quickly and safely charged with a
consistent current.
Step 6: Base charge with a constant voltage
The battery is charged at a constant charge end
voltage until it is fully charged.
Step 7: Analysis
Once the battery is fully charged, the charging
process will stop.
Step 8: Equalisation charge
If the battery is fully charged and drops to 12.8V
within 2 minutes, another charging process will
begin automatically.
Step 9: Maintenance charging
The charger monitors the battery capacity. Once
the battery falls below 12.8 V, the charger will emit a
charging pulse. This maintains the battery’s highest
possible charging level.
Summary of Contents for LT20
Page 15: ...Deutsch 15 ...
Page 16: ......
Page 29: ...English 29 ...
Page 30: ......
Page 43: ...Français 43 ...
Page 44: ......
Page 57: ...Italiano 57 ...
Page 58: ......
Page 71: ...Česky 71 ...
Page 72: ......
Page 85: ...Slovenčina 85 ...
Page 86: ......
Page 87: ...AEG is a registered trademark used under license from AB Electrolux publ ...