44
the drain hose and standpipe.
The end of the drain hose must
always be
ventilated
, i.e. the inside
diameter of the drain pipe must be
larger than the outside diameter of
the drain hose.
The drain hose must not be kinked.
When discharging into a standpipe
ensure that the top of the standpipe is
no more than 90 cm (35.4'') and no less
than 60 cm (23.6'') above floor level.
The drain hose may be extended to a
maximum of 4 metres. An additional
drain hose and joining piece is available
from your local Service Force Centre.
The joining piece must have an internal diameter of
18 mm.
If your drain hose looks like this (see the relevant
picture) you do not require the “U” piece”. Just push
the hose firmly into the standpipe.
2. Onto a sink outlet spigot.
If the outlet spigot has not been used before, remove any blanking plug that may
be in place.
Push the drain hose onto the spigot and secure with a clip, ensure a loop is formed
in the drain hose (see diagram) to prevent waste from the sink entering the wash-
ing machine.
The drain hose may be extended to a maximum of 4
metres. An additional drain hose and joining piece is
available from your local Service Force Centre. The
joining piece must have an internal diameter of 18
mm.
Installation
30 cm (12")
38 mm (1.5)
standpipe
diameter
3
pi
n
M
ax
.
90
c
m
.
(35
.
4")
Mi
n
.
60
c
m
.
(23
.
6")
Loop