6.
Pull out the emergency emptying hose,
place it in the container and remove its
cap.
7.
When no more water comes out, un-
screw the pump cover by turning it anti-
clockwise and remove the filter. Use pli-
ers, if necessary. Always keep a rag near-
by to dry up any water spillages when
removing the cover.
Clean the filter under a tap, to remove
any traces of fluff.
8.
Remove foreign bodies and fluff from
the filter seat and from the pump im-
peller.
9.
Check carefully whether the pump im-
peller rotates (it rotates jerkily). If it
doesn’t rotate, please contact your Serv-
ice Centre.
10. Put the cap back on the emergency emp-
tying hose and place the latter back in
its seat.
11. Replace the filter into the pump by in-
serting it correctly into the special
guides. Screw the pump cover firmly by
turning it clockwise.
12. Refit the flap and close the pump door.
WARNING!
When the appliance is in use and depending on the programme selected there can be hot
water in the pump.
24
Care and cleaning