Set the hose correctly by loosening the ring
nut. After positioning the inlet hose, be sure
to tighten the ring nut again to prevent
leaks.
Do not connect to a hot water supply.
Model 16800
The inlet hose is provided with a water stop
device, which protects against damage
caused by water leaks in the hose which
could develop due to natural ageing of the
hose. This fault is shown by a red sector in
the window “A”. Should this occur, turn the
water tap off and refer to your Service Force
Centre to replace the hose.
Water drainage
The appliance drain hose should hook into a standpipe, the hook in the
drain hose is formed using the plastic “U-Piece” supplied. The standpipe
should have an internal diameter of approximately 38 mm (see dia-
gram) thus ensuring there is an air break between the drain hose and
standpipe.
When discharging into a stand-
pipe ensure that the top of the
curve in the hose end is no
more than 90 cm (35.4”) and
no less than 60 cm (23.6”)
above floor level.
The upright standpipe should have a mini-
mum length of 30 cm (12”) from the bottom
of the elbow to the top of the pipe (see dia-
gram). Make sure that it is designed in such a
way that the end of the drain hose cannot be
covered with water.
51
Installation
A
3 pin
Max. 90 cm.(35.4")
Min.60 cm.(23.6")
Min. 30 cm.(12")
38 mm.(1/ ") diameter
standpipe
1
2
132999111.qxd 1/4/02 10:04 AM Pagina 51 (Nero/Process Black pellicola)