TROUBLESHOOTING
WARNING!
Refer to Safety chapters.
16.1
Introduction
The appliance does not start or it stops during operation.
First try to find a solution to the problem (refer to the table). If the problem persists,
contact the Authorised Service Centre.
WARNING!
Deactivate the appliance before carrying out any check.
In case of major problems, the acoustic signals operate, the display shows an
alarm code and the
Start/Pause
button may flash continuously:
•
- The mains supply is unstable. Wait until the mains supply is stable.
•
- No communication between electronic elements of the appliance. Switch it
off and switch on again. The programme was not finished properly or the appliance
stopped too early. If the alarm code appears again, contact the Authorised Service
Centre.
•
- The anti-flood device is on. Disconnect the appliance and close the water
tap. Contact the Authorised Service Centre.
•
- The appliance does not fill with water properly. After the proper check, start
the appliance again by pressing Start/Pause button the appliance tries to resume
the cycle . If the error persists the alarm code will appear again.
•
- The appliance does not drain the water.
•
- The appliance door is open or not closed correctly. Please check the door!
If the appliance is overloaded, remove some items from the drum
and/or hold the door shut while touching the Start/Pause button until
the indicator
stops flashing (see the picture below).