Programmes
Load
(kg)
Energy
consump-
tion (kWh)
Water
consump-
tion (litre)
Approxi-
mate pro-
gramme
duration
(minutes)
Remain-
ing mois-
ture (%)
1)
Standard 40°C cotton
4
0,51
40
226
44
1)
At the end of spin phase.
Off Mode (W)
Left On Mode (W)
0.30
0.30
The information given in the chart above is compliant with the EU Commission regulation
1015/2010 implementing directive 2009/125/EC
15.
TECHNICAL DATA
Dimension
Width/ Height/ Depth/
Total depth
600 mm/ 850 mm/ 571 mm/ 600 mm
Electrical connection
Voltage
Overall power
Fuse
Frequency
230-240 V
2200 W
13 A
50 Hz
Level of protection against ingress of solid particles
and moisture ensured by the protective cover, ex-
cept where the low voltage equipment has no pro-
tection against moisture
IPX4
Water supply pressure
1)
Minimum
Maximum
0,5 bar (0,05 MPa)
8 bar (0,8 MPa)
Water supply
2)
Cold water
Maximum Load
Cotton
8 kg
Energy Efficiency Class
A+++ -20%
Spin Speed
Maximum
1600 rpm
1)
The appliance works correctly if the water pressure is not lower than 0.05 MPa (0.5 bar). If you cannot
connect the water inlet hose to the cold water tap of the primary hydraulic system, connect it to your
domestic cold water storage system. Make sure not to exceed a distance of 5.02 m (16.5 ft) between the
appliance inlet hose and the bottom of the water storage tank.
2)
Connect the water inlet hose to a water tap with a 3/4'' thread.
ENGLISH
33