5. Press / of the timer to set the
power level.
Power levels
Refer to “Technical data” chapter.
CAUTION!
Make sure that the selected
power fits the house installation
fuses.
• P72 — 7200 W
• P15 — 1500 W
• P20 — 2000 W
• P25 — 2500 W
• P30 — 3000 W
• P35 — 3500 W
• P40 — 4000 W
• P45 — 4500 W
• P50 — 5000 W
• P60 — 6000 W
5.14 Power management
If multiple zones are active and the
consumed power exceeds the limitation of
the power supply, this function divides the
available power between all cooking zones.
The hob controls heat settings to protect the
fuses of the house installation.
• Cooking zones are grouped according to
the location and number of the phases in
the hob. Each phase has a maximum
electricity loading (3700 W). If the hob
reaches the limit of maximum available
power within one phase or the selected
total power limit, the power of the cooking
zones will be automatically reduced.
• The heat setting of the cooking zone
selected last is always prioritised. The
remaining power will be divided between
the previously activated cooking zones in
reverse order of selection.
• The heat setting display of the reduced
zones changes between the initially
selected heat setting and the reduced
heat setting.
• Wait until the display stops flashing or
reduce the heat setting of the cooking
zone selected last. The cooking zones will
continue operating with the reduced heat
setting. Change the heat settings of the
cooking zones manually, if necessary.
Power management with Power limitation
When you set the Power limitation function to
6000 W or less, the power of the hob is
divided among all cooking zones.
Refer to the illustration for possible
combinations in which power can be
distributed among the cooking zones.
When you set the Power limitation function to
more than 6000 W, the power of the hob is
divided among the sections indicated below.
6. HINTS AND TIPS
WARNING!
Refer to Safety chapters.
14
ENGLISH