3.2 Built-in hobs
Only use the built-in hobs after you assemble
the hob into correct built-in units and work
surfaces that align to the standards.
3.3 Connection cable
• The hob is supplied with a connection
cable.
• Replace the damaged mains cable only
with the spare parts cable. Speak to your
local Authorised Service Centre.
WARNING!
All electrical connections must
be made by a qualified
electrician.
CAUTION!
Do not drill or solder the wire
ends. It is forbidden.
CAUTION!
Do not connect the cable without
cable end sleeve.
Two-phase connection
1. Remove the cable end sleeve from black
and brown wires.
2. Remove an insulation of the brown and
black cable ends.
3. Apply a new wire end sleeve of 1.5 mm²
on each cable end (special tool required).
Cable cross section
N
L1
N
L
230V~
400V 2~N
L2
One-phase connection - 230 V~
Two-phase connection - 400 V 2 ~ N
Green - yellow
Green - yellow
N
Blue and blue
Blue and blue
N
L
Black and brown
Black
L1
Brown
L2
3.4 Assembly
If you install the hob under a hood, please
see the installation instructions of the hood
for the minimum distance between the
appliances.
min.
50mm
min.
500mm
If the appliance is installed above a drawer,
the hob ventilation can warm up the items
ENGLISH