--------------------------------------------------------------------------3/17------------------------------------------------------------------------------------
1.1
BLE HID-keyboard in the Interface selection
To use the Bluetooth HID function the appropriate interface selection in ARE H9 BLE must
selected under the menu item
Set interface
.
BLE HID Keybd.
Set Interface
USB
Set Interface
HID Keyboard
Set Interface
BLE HID Keybd.
The selection is made by the arrow keys and confirmed by pressing the main button.
If there is active no connection (or pairing) this time, the following screen on the ARE H9 BLE is
to see:
Await Connection
Cancel ?
This screen will stay active until it is cancelled from the user by pressing both arrow keys, or until
an active Bluetooth Low Energy connection is established.
When HID-keyboard is selected as interface the ARE H9 changes automatically to the operation
mode Online/Keyboard, only in this operation mode transponder ID-numbers are transmitted to an
attached device like input from a HID-keyboard. While the interface selection is
HID-keyboard
the operation modes
Handshake
and
Database
are not available.