Instructions
Unpacking
• Remove any protective foils and transport packaging
from the device that may be present.
• Unwind the cable completely.
Electrical connection
• Make sure that the iron voltage (see name plate) and
the line voltage match.
• Turn the switches to 0 and the lowest level.
• The mains plug should only be inserted into a cor-
rectly installed 230 V ~ 50 Hz socket with earthing
contact.
Connected Wattage
The device can consume 2000 Watts:
With this connected load a separate supply line pro-
tected by a 16 A household circuit breaker is recommen-
ded.
CAUTION: OVERLOAD
• If you use extension leads, these should have a
cable cross-section of at least 1.5 mm
2
.
• Do not use any multiple sockets, as this device is
too powerful.
Safety Switch
Your radiator has a safety switch which turns off the elec-
tricity as soon as the device falls over. The safety switch
prevents dangerous situations caused by overheating.
CAUTION:
Always place the device in an upright position in order
that it is stable and in order to prevent malfunctions.
.
NOTE:
The device switches on again automatically as soon as
it is placed in an upright position.
Function Switch
0 =
OFF
= Cold air
I
= Hot air (1000 W)
II = Hot air (2000 W)
NOTE:
Select low power, for example, for a small room. If this
is not enough, please switch to the high level.
Levels/Heating Power
By regularly switching the radiator on and off , the
thermostat ensures that the desired temperature is
maintained.
Lowest level
Highest level
In order to fi nd the ideal thermostat setting, please
proceed as follows:
• Turn the thermostat control to the highest level.
• As soon as the desired temperature has been reached,
turn the thermostat control slowly down until the
radiator turns itself off . The control lamp on the
switch goes off .
• The radiator will now automatically stay at the
desired temperature.
CAUTION:
When the device is no longer being used you should
always remove the mains plug.
Oscillation
In order to achieve uniform heating and ventilation the
device is also equipped with an oscillation function. This
function is available in all three modes of operation.
• Press the switch on the bottom of the device in order
to switch oscillation mode on and off .
CAUTION:
• Never move the swivel mechanism by hand, as
otherwise the mechanism might be damaged.
• Only the switch should be used to change the
direction of ventilation.
Cold air operation
If you would like to use the device as a ventilator please
move the function switch to the ventilator symbol and
turn the temperature control to the highest position.
Turning Off
If you would like to switch the device off , turn the
switch to the lowest level or 0 and then remove the plug
from the socket. The control lamp goes off .
Overheating Protection
• The device is equipped with an overheating protec-
tion that switches the device automatically off in
case of overheating. Shift the function switch to „0“
position and pull out plug out of the socket. Let the
device cool down for about
10 minutes before using it again.