• Replace the damaged mains cable
only with the spare parts cable. Speak
to your local Authorised Service
Center.
WARNING!
All electrical connections
must be made by a qualified
electrician.
CAUTION!
Do not drill or solder the
wire ends. This is strictly
forbidden!
CAUTION!
Do not connect the cable
without cable end sleeve.
Two-phase connection
1.
Remove the cable end sleeve from
black and brown wires.
2.
Remove an insulation of the brown
and black cable ends.
3.
Apply a new wire end sleeve of 1.5
mm² on each cable end. (special tool
required).
Cable cross section
N
L1
N
L
230V~
400V 2~N
L2
One-phase connection - 230 V~
Two-phase connection - 400 V 2 ~ N
Green - yellow
Green - yellow
N
Blue and blue
Blue and blue
N
L
Black and brown
Black
L1
Brown
L2
8.4
Assembly
min.
50mm
min.
500mm
min.
2mm
www.aeg.com
16