9.
TECHNICAL DATA
9.1
Hob dimensions
Width
745 mm
Depth
515 mm
9.2
Bypass diameters
BURNER
Ø BYPASS 1/100 mm
Rapid
52
Semi-rapid
35
Auxiliary
32
9.3
Other technical data
TOTAL POWER:
Gas original:
G20 (2H) 20 mbar = 8,9 kW
Electric supply:
220-240 V ~ 50/60 Hz
3 core flexible cable with non rewireable plug fitted with a 3 amp
cartridge fuse
Appliance category:
I2H
Gas connection:
R 1/2"
Appliance class:
3
9.4
Gas burners for NATURAL GAS G20 20 mbar
BURNER
NORMAL POWER kW MINIMUM POWER
kW
INJECTOR MARK
Rapid
2,9
1,2
120B
Semi-rapid
2,0
0,75
102
Auxiliary
1,0
0,5
73F
10.
ENERGY EFFICIENCY
10.1
Product information according to EU 66/2014
Model identification
HG755820UM
Type of hob
Built-in hob
Number of gas burners
5
ENGLISH
17
Summary of Contents for HG755820