CAUTION!
Install the appliance only on
a worktop with flat surface.
8.9
Possibilities for insertion
The panel installed below the hob must
be easy to remove and let an easy access
in case a technical assistance
intervention is necessary.
Kitchen unit with door or drawer
min 6 mm
min 30 mm
60 mm
b
a
min 5 mm
(max 150 mm)
A.
Removable panel
B.
Space for connections
Kitchen unit with oven
The electrical connection of the hob and
the oven must be installed separately for
safety reasons and to let easy remove
oven from the unit.
9.
TECHNICAL DATA
9.1
Hob dimensions
Width
740 mm
Depth
510 mm
9.2
Bypass diameters
BURNER
Ø BYPASS 1/100 mm
Multi Crown
56
Semi-rapid
32
Auxiliary
28
9.3
Other technical data
TOTAL POWER:
Gas original:
G20 (2H) 20 mbar = 10,5 kW
Gas replacement:
G30 (3+) 28-30 mbar = 745 g/h
G31 (3+) 37 mbar = 732 g/h
Electric supply:
220-240 V ~ 50/60 Hz
3 core flexible cable with non rewireable plug fitted with a 3 amp
cartridge fuse