Liquid gas
Use the rubber pipe holder for liquid
gas. Always engage the gasket. Then
continue with the gas connection.
The flexible pipe is prepared for apply
when:
– it can not get hot more than room
temperature, higher than 30°C;
– it is no longer than 1500 mm;
– it shows no throttles;
– it is not subject to traction or torsion;
– it does not get in touch with cutting
edges or corners;
– it can be easily examined in order to
make sure its condition.
The control of preservation of the flexi-
ble pipe consists in checking that:
– it does not show cracks, cuts, marks of
burnings on the two ends and on its
full length;
– the material is not hardened, but
shows its correct elasticity;
– the fastening clamps are not rusted;
– expired term is not due.
If one or more defects are visible, do not
repair the pipe, but replace it.
When installation is complete,
make sure that the seal of each
pipe fitting is correct. Use a
soapy solution,
not a flame
!
8.2
Injectors replacement
1.
Remove the pan supports.
2.
Remove the caps and crowns of the
burner.
3.
With a socket spanner 7 remove the
injectors and replace them with the
ones which are necessary for the
type of gas you use (see table in
"Technical Information" chapter).
4.
Assemble the parts, follow the same
procedure backwards.
5.
Replace the rating plate (it is near
the gas supply pipe) with the one for
the new type of gas supply. You can
find this plate in the package sup-
plied with the appliance.
If the supply gas pressure is changeable
or different from the necessary pressure,
you must fit an applicable pressure ad-
juster on the gas supply pipe.
8.3
Adjustment of minimum
level
To adjust the minimum level of the burn-
ers:
1.
Light the burner.
2.
Turn the knob on the minimum posi-
tion.
3.
Remove the control knob.
4.
With a thin screwdriver, adjust the
by-pass screw position.
A
A)
The by-pass screw
• If you change from natural gas G20 20
mbar (or natural gas G20 13 mbar
1)
)
to liquid gas, fully tighten the by-pass
screw in.
• If you change from liquid gas to natu-
ral gas G20 20 mbar, undo the by-pass
screw approximately 1/4 of a turn.
• If you change from natural gas G20 20
mbar to natural gas G20 13 mbar
1)
un-
do the by-pass screw about 1/4 of a
turn.
• If you change from liquid gas to natu-
ral gas G20 13 mbar
1)
, undo the by-
pass screw about 1/2 of a turn.
• If you change from natural gas G20 13
mbar
1)
to natural gas G20 20 mbar to
tighten the by-pass screw about 1/4 of
a turn.
WARNING!
Make sure the flame does not go
out when you quickly turn the
knob from the maximum position
to the minimum position.
1)
only for Russia
12 www.aeg.com