5.

Replace the rating plate (it is near the

gas supply pipe) with the one for the

new type of gas supply. You can find

this plate in the package supplied

with the appliance.

If the supply gas pressure is changeable

or different from the necessary pressure,

you must fit an applicable pressure

adjuster on the gas supply pipe.

8.5 

Adjustment of minimum

level

To adjust the minimum level of the

burners:

1.

Light the burner.

2.

Turn the knob on the minimum

position.

3.

Remove the knob.

4.

With a thin screwdriver, adjust the

bypass screw position (A).

A

5.

If you change:

• from natural gas G20 20 mbar to

liquid gas, fully tighten the bypass

screw in.

• from liquid gas to natural gas G20

20 mbar, undo the bypass screw

approximately 1/4 of a turn.

WARNING!

Make sure the flame does

not go out when you quickly

turn the knob from the

maximum position to the

minimum position.

8.6 

Electrical connection

• Do not pull the mains cable to

disconnect the appliance. Always pull

the mains plug (if applicable).

• The appliance must not be connected

with an extension cable, an adapter or

a multiple socket. There is a risk of

fire.

• Do not let the power cable to heat up

to a temperature of more than 90° C.

The cable should be guided by means

of clamps fixed to the side of the

cabinet, in order to avoid any contact

with the equipment beneath the

cooktop.

• Make sure that there is access to the

mains plug after the installation.

Electrical Requirements

Permanent electrical installation must

agree with the latest I.E.E. Regulations

and local Electricity Board regulations.

For your own safety the installation must

be done by a qualified electrician (e.g.

your local Electricity Board, or a

contractor who is on the roll of the

National Inspection Council for Electrical

Installation Contracting [NICEIC]).

The manufacturer refuses

to be held responsible, if

these safety measures are

not abided by.

Supply connections

This hob has to be connected to 220-240

V (~ 50/60 Hz ) electricity supply.

The hob has a terminal block which is

marked as follows:

L

 — Live terminal

N

 — Neutral terminal

 or 

E

 — Earth terminal

Before carrying out the connection,

make sure:

1.

The limiter valve and the electrical

system can take the appliance load

(see the rating plate)

2.

The supply system is equipped with

an efficient earth connection in

compliance with the current

standards and regulations

3.

The outlet or omnipolar switch used

for connection is easily accessible

with the appliance installed.

The appliance is supplied with a 3 core

flexible power cable with a 3 amp plug. If

it is necessary to change the fuse, use a 3

amp ASTA-approved (BS 1362) fuse.

www.aeg.com

14

Summary of Contents for HG653431

Page 1: ...USER MANUAL EN User Manual Hob HG653431 ...

Page 2: ... service information www aeg com webselfservice Register your product for better service www registeraeg com Buy Accessories Consumables and Original spare parts for your appliance www aeg com shop CUSTOMER CARE AND SERVICE Always use original spare parts When contacting our Authorised Service Centre ensure that you have the following data available Model PNC Serial Number The information can be f...

Page 3: ...cessible parts are hot If the appliance has a child safety device this should be activated Children shall not carry out cleaning and user maintenance of the appliance without supervision Children aged 3 years and under must be kept away from this appliance when it is in operation at all times 1 2 General Safety WARNING The appliance and its accessible parts become hot during use Care should be tak...

Page 4: ...rd is damaged it must be replaced by the manufacturer an authorized Service or similarly qualified persons in order to avoid a hazard Where the appliance is directly connected to the power supply an all pole isolating switch with a contact gap is required Complete disconnection in compliance with the conditions specified in overvoltage category III must be guaranteed The earth cable is excluded fr...

Page 5: ... The panel must be removable for servicing Screws used to fix the panel must be accessible after installation 2 2 Electrical Connection WARNING Risk of fire and electrical shock All electrical connections should be made by a qualified electrician The appliance must be earthed Before carrying out any operation make sure that the appliance is disconnected from the power supply Make sure that the par...

Page 6: ...after each use Do not put cutlery or saucepan lids on the cooking zones They can become hot Do not operate the appliance with wet hands or when it has contact with water Do not use the appliance as a work surface or as a storage surface When you place food into hot oil it may splash WARNING Risk of fire and explosion Fats and oil when heated can release flammable vapours Keep flames or heated obje...

Page 7: ...he buttons knobs or gaskets from the control panel Water may get inside the appliance and cause damage Clean regularly the appliance to prevent the deterioration of the surface material Deactivate the appliance and let it cool down before you clean it Disconnect the appliance from the electrical supply before maintenance Do not use water spray and steam to clean the appliance Clean the appliance w...

Page 8: ...D C A Burner cap B Burner crown C Ignition candle D Thermocouple 4 2 Ignition of the burner Always light the burner before you put on the cookware WARNING Be very careful when you use open fire in the kitchen environment The manufacturer declines any responsibility in case of the flame misuse 1 Push the control knob down and turn it counterclockwise to the maximum gas supply position 2 Keep the co...

Page 9: ...minute The spark generator can start automatically when you switch on the mains after installation or a power cut It is normal Each control knob has a pilot light It lights up when you turn the control knob 4 3 Turning the burner off To put the flame out turn the knob to the off position WARNING Always turn the flame down or switch it off before you remove the pans from the burner 5 HINTS AND TIPS...

Page 10: ...s or between the rims of the burners and the frame if applicable Wash stainless steel parts with water and then dry them with a soft cloth 6 2 Pan supports The pan supports are not resistant to washing in a dishwasher They must be washed by hand 1 Remove the pan supports to easily clean the hob Be very careful when you replace the pan supports to prevent the hob top from damage 2 The enamel coatin...

Page 11: ...ossible cause Remedy There is no spark when you try to activate the spark gen erator The hob is not connected to an electrical supply or it is connected incorrectly Check if the hob is correctly connected to the electrical supply The fuse is blown Make sure that the fuse is the cause of the malfunction If the fuse is blown again and again contact a quali fied electrician Burner cap and crown are p...

Page 12: ...r 8 2 Important safety requirements This hob must be installed in accordance with the Gas Safety Installation and Use Regulations Current Edition and the IEE Wiring Regulations Current Edition For appliances installed in the Republic of Ireland please refer to NSAI Domestic Gas Installation I S 813 Current Editions and the ETCI Rules for Electrical Installations Provision for ventilation Detailed ...

Page 13: ... the R 1 2 threaded elbow adjustment is fixed so that the washer is fitted between the components as shown in the diagram Screw the parts together without using excessive force A End of shaft with nut B Elbow supplied with the appliance Connection to the gas supply should be with either rigid or semi rigid pipe i e steel or copper The connection should be suitable for connecting to R 1 2 1 2 BSP m...

Page 14: ...means of clamps fixed to the side of the cabinet in order to avoid any contact with the equipment beneath the cooktop Make sure that there is access to the mains plug after the installation Electrical Requirements Permanent electrical installation must agree with the latest I E E Regulations and local Electricity Board regulations For your own safety the installation must be done by a qualified el...

Page 15: ...cable use only H03V2V2 F T90 or equivalent type Make sure that the cable section is applicable to the voltage load and the working temperature The yellow green earth wire B must be approximately 2 cm longer than the live and neutral wire A A B 1 Connect the green and yellow earth wire to the terminal which is marked with the letter E or the earth symbol or coloured green and yellow 2 Connect the b...

Page 16: ...distance of 50 mm to the left or right from the edge of the hob 4 B A A supplied seal B supplied brackets 5 CAUTION Install the appliance only on a worktop with flat surface 8 9 Possibilities for insertion The panel installed below the hob must be easy to remove and let an easy access in case a technical assistance intervention is necessary Kitchen unit with door or drawer min 6 mm www aeg com 16 ...

Page 17: ...YPASS 1 100 mm Rapid 42 Semi rapid 32 Auxiliary 28 9 3 Other technical data TOTAL POWER Gas original G20 2H 20 mbar 7 7 kW Gas replacement G30 3 28 30 mbar 545 g h G31 3 37 mbar 536 g h Electric supply 220 240 V 50 60 Hz 3 core flexible cable with non rewireable plug fitted with a 3 amp cartridge fuse Appliance category II2H3 Gas connection R 1 2 Appliance class 3 9 4 Gas burners for NATURAL GAS G...

Page 18: ...use of energy General 10 2 Energy saving Before use make sure that the burners and pan supports are assembled correctly Use cookware with diameters applicable to the size of burners Center the pot on the burner When you heat up water use only the amount you need If it is possible always put the lids on the cookware When the liquid starts to boil turn down the flame to barely simmer the liquid If i...

Page 19: ...ENGLISH 19 ...

Page 20: ...www aeg com shop 867334555 A 502016 ...

Reviews: