• Remove all the packaging.

• Do not install or use a damaged

appliance.

• Follow the installation instruction

supplied with the appliance.

• Keep the minimum distance from the

other appliances and units.

• Always take care when moving the

appliance as it is heavy. Always use

safety gloves and enclosed footwear.

• Seal the cut surfaces with a sealant to

prevent moisture to cause swelling.

• Protect the bottom of the appliance

from steam and moisture.

• Do not install the appliance adjacent

to a door or under a window. This

prevents hot cookware to fall from the

appliance when the door or the

window is opened.

• If the appliance is installed above

drawers make sure that the space,

between the bottom of the appliance

and the upper drawer, is sufficient for

air circulation.

• The underside of the appliance can

get hot when in use. If an oven has

not been fitted underneath the hob

and underside of the appliance is

accessible and could allow a user or

items stored beneath the hob to

come in direct contact with the

underside of the hob, an intermediate

protection panel must be fitted.

• Plywood or kitchen carcass material is

acceptable for the panel.

• The panel must be removable for

servicing. Screws used to fix the panel

must be accessible after installation.

2.2 

Electrical Connection

WARNING!

Risk of fire and electrical

shock.

• All electrical connections should be

made by a qualified electrician.

• The appliance must be earthed.

• Before carrying out any operation

make sure that the appliance is

disconnected from the power supply.

• Make sure that the electrical

information on the rating plate agrees

with the power supply. If not, contact

an electrician.

• Make sure the appliance is installed

correctly. Loose and incorrect

electricity mains cable or plug (if

applicable) can make the terminal

become too hot.

• Use the correct electricity mains

cable.

• Do not let the electricity mains cable

tangle.

• Make sure that a shock protection is

installed.

• Use the strain relief clamp on the

cable.

• Make sure the mains cable or plug (if

applicable) does not touch the hot

appliance or hot cookware, when you

connect the appliance to the near

sockets

• Do not use multi-plug adapters and

extension cables.

• Make sure not to cause damage to

the mains plug (if applicable) or to the

mains cable. Contact our Authorised

Service Centre or an electrician to

change a damaged mains cable.

• The shock protection of live and

insulated parts must be fastened in

such a way that it cannot be removed

without tools.

• Connect the mains plug to the mains

socket only at the end of the

installation. Make sure that there is

access to the mains plug after the

installation.

• If the mains socket is loose, do not

connect the mains plug.

• Do not pull the mains cable to

disconnect the appliance. Always pull

the mains plug.

• Use only correct isolation devices: line

protecting cut-outs, fuses (screw type

fuses removed from the holder), earth

leakage trips and contactors.

• The electrical installation must have

an isolation device which lets you

disconnect the appliance from the

mains at all poles. The isolation

device must have a contact opening

width of minimum 3 mm.

2.3 

Gas connection

• All gas connections should be made

by a qualified person.

• Before installation, make sure that the

local distribution conditions (nature of

ENGLISH

5

Summary of Contents for HG644350

Page 1: ...EN User Manual Hob HG755550 ...

Page 2: ...ew minutes reading to get the very best from it Visit our website for Get usage advice brochures trouble shooter service information www aeg com webselfservice Register your product for better service www registeraeg com Buy Accessories Consumables and Original spare parts for your appliance www aeg com shop CUSTOMER CARE AND SERVICE Always use original spare parts When contacting our Authorised S...

Page 3: ...packaging away from children and dispose of it appropriately Keep children and pets away from the appliance when it operates or when it cools down Accessible parts are hot If the appliance has a child safety device this should be activated Children shall not carry out cleaning and user maintenance of the appliance without supervision Children aged 3 years and under must be kept away from this appl...

Page 4: ...power supply an all pole isolating switch with a contact gap is required Complete disconnection in compliance with the conditions specified in overvoltage category III must be guaranteed The earth cable is excluded from this When you route the mains cable make sure that the cable doesn t come into direct contact for example using insulating sleeving with parts that can reach temperatures of more t...

Page 5: ...the electrical information on the rating plate agrees with the power supply If not contact an electrician Make sure the appliance is installed correctly Loose and incorrect electricity mains cable or plug if applicable can make the terminal become too hot Use the correct electricity mains cable Do not let the electricity mains cable tangle Make sure that a shock protection is installed Use the str...

Page 6: ...d remnants can cause fire at a lower temperature than oil used for the first time Do not put flammable products or items that are wet with flammable products in near or on the appliance WARNING Risk of damage to the appliance Do not keep hot cookware on the control panel Do not let cookware to boil dry Be careful not to let objects or cookware fall on the appliance The surface can be damaged Do no...

Page 7: ...k of injury or suffocation Contact your municipal authority for information on how to discard the appliance correctly Disconnect the appliance from the mains supply Cut off the mains electrical cable close to the appliance and dispose of it Flat the external gas pipes 2 7 Service To repair the appliance contact an Authorised Service Centre Use original spare parts only 3 PRODUCT DESCRIPTION 3 1 Co...

Page 8: ...RNING Do not keep the control knob pushed for more than 15 seconds If the burner does not light after 15 seconds release the control knob turn it into off position and try to light the burner again after minimum 1 minute CAUTION In the absence of electricity you can ignite the burner without electrical device in this case approach the burner with a flame turn the control knob counter clockwise to ...

Page 9: ...front edge of the cooktop CAUTION Make sure that the pots are placed centrally on the burner in order to get maximum stability and to get lower gas consumption 5 2 Diameters of cookware Use cookware with diameters applicable to the size of burners Burner Diameter of cookware mm Triple Crown 180 260 Rapid 120 260 Semi rapid front 120 180 Semi rapid rear 120 240 Auxiliary 80 160 6 CARE AND CLEANING ...

Page 10: ...avoid burns Remove when the hob is sufficiently cool limescale rings water rings fat stains shiny metallic discoloration Clean the hob with a moist cloth and non abrasive detergent After cleaning wipe the hob dry with a soft cloth To clean the enamelled parts cap and crown wash them with warm soapy water and dry them carefully before you put them back on 6 4 Cleaning the spark plug This feature is...

Page 11: ... after ignition Thermocouple is not heated up sufficiently After lightning the flame keep the knob pushed for equal or less than 10 sec onds The flame ring is uneven Burner crown is blocked with food residues Make sure that the injector is not blocked and the burner crown is clean 7 2 If you cannot find a solution If you cannot find a solution to the problem yourself contact your dealer or an Auth...

Page 12: ...in accordance with the Gas Safety Installation and Use Regulations Current Edition and the IEE Wiring Regulations Current Edition For appliances installed in the Republic of Ireland please refer to NSAI Domestic Gas Installation I S 813 Current Editions and the ETCI Rules for Electrical Installations Provision for ventilation Detailed recommendations are contained in the following British Standard...

Page 13: ...bility should the above instructions or any of the other safety instructions incorporated in this instruction booklet be ignored On the end of the shaft which includes the G 1 2 threaded elbow adjustment is fixed so that the washer is fitted between the components as shown in the diagram Screw the parts together without using excessive force A B C A End of shaft with nut B Washer C Elbow Connectio...

Page 14: ...tion to the minimum position 8 6 Electrical connection Do not pull the mains cable to disconnect the appliance Always pull the mains plug if applicable The appliance must not be connected with an extension cable an adapter or a multiple socket There is a risk of fire Do not let the power cable to heat up to a temperature of more than 90 C The cable should be guided by means of clamps fixed to the ...

Page 15: ...nt of electric cable must be carried out exclusively by the service force centre or by personnel with similar competencies in accordance with the current regulations To replace the connection cable use only H03V2V2 F T90 or equivalent type Make sure that the cable section is applicable to the voltage load and the working temperature The yellow green earth wire B must be approximately 2 cm longer t...

Page 16: ... mm min 170 mm 30 mm 480 mm min 600 mm 4 50 mm 400 mm If a furniture unit is installed at a distance of 400 mm above the hob there must be a minimum safety distance of 50 mm to the left or right from the edge of the hob 5 6 7 8 9 www aeg com 16 ...

Page 17: ...intervention is necessary Kitchen unit with door or drawer min 6 mm min 5 mm max 150 mm min 40 mm 60 mm B A A Removable panel B Space for connections Kitchen unit with oven The electrical connection of the hob and the oven must be installed separately for safety reasons and to let easy remove oven from the unit 9 TECHNICAL DATA 9 1 Hob dimensions Width 745 mm Depth 510 mm 9 2 Bypass diameters BURN...

Page 18: ...H3 Gas connection R 1 2 Appliance class 3 9 4 Gas burners for NATURAL GAS G20 20 mbar BURNER NORMAL POWER kW MINIMUM POWER kW INJECTOR MARK 1 100 mm Triple Crown 4 0 1 4 146 Rapid 2 5 0 75 108x Semi rapid 2 0 0 75 96x Auxiliary 1 0 0 45 70 9 5 Gas burners for LPG G30 G31 28 30 37 mbar BURNER NORMAL POWER kW MINIMUM POWER kW INJECTOR MARK 1 100 mm NOMINAL GAS FLOW g h G30 28 30 mbar G31 37 mbar Tri...

Page 19: ...orrectly Use cookware with diameters applicable to the size of burners Center the pot on the burner When you heat up water use only the amount you need If it is possible always put the lids on the cookware When the liquid starts to boil turn down the flame to barely simmer the liquid If it is possible use a pressure cooker Refer to its user manual 11 ENVIRONMENT CONCERNS Please recycle all materia...

Page 20: ...www aeg com shop 867329140 C 152016 ...

Reviews: