The power of the cooking zones can be
different in some small range from the
data in the table. It changes with the
material and dimensions of the
cookware.
For optimal cooking results use
cookware no larger than the diameter in
the table.
9.3
Bypass diameters
BURNER
Ø BYPASS 1/100 mm
Dual (internal crown)
29
Dual (external crown)
57
9.4
Other technical data
TOTAL POWER:
Gas original:
G20 (2H) 20 mbar = 5 kW
Gas replacement:
G30 (3+) 28-30 mbar = 334 g/h
G31 (3+) 37 mbar = 329 g/h
Electric zones:
7,2 kW
Electric supply:
220-240 V ~ 50-60 Hz
Appliance category:
II2H3+
Gas connection:
G 1/2"
Appliance class:
3
9.5
Gas burners for NATURAL GAS G20 20 mbar
BURNER
NORMAL POWER
kW
MINIMUM POWER
kW
INJECTOR MARK
Dual
5,0
1,42
70 / 115
Dual (internal crown) 0,8
0,33
70
9.6
Gas burners for LPG G30/G31 28-30/37 mbar
BURNER
NORMAL
POWER kW
MINIMUM
POWER kW
INJECTOR
MARK
NOMINAL GAS FLOW g/h
G30 28-30
mbar
G31 37 mbar
Dual
4,6
1,42
46 / 72
334
329
Dual (inter-
nal crown)
0,8
0,33
46
58
57
www.aeg.com